| Parameter | Value |
|---|---|
| -25 °C ... 85 °C (cable, flexible installation) | |
| Note | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Coding | A - standard |
| Torque | 3 Nm ... 4 Nm (Installation-side) |
| Cable type | TPE litz wire |
| Wire colors | Brown, blue, white, gray, pink, green, yellow, red |
| Mounting type | Front mounting Square flange |
| Rated voltage | 30 V |
| Status display | No |
| AWG signal line | 24 |
| Length of cable | 0.5 m |
| Contact material | CuZn |
| Material, knurls | Zinc die-cast, nickel-plated |
| Pollution degree | 3 |
| Sealing material | FKM |
| Connection method | Individual wires |
| Conductor material | Tin-plated Cu litz wires |
| Number of positions | 8 |
| Rated surge voltage | 0.8 kV |
| Test voltage, cable | 2000 V AC |
| Conductor resistance | ≤ 57.6 mΩ/m |
| Degree of protection | IP67 |
| Overvoltage category | II |
| Insulation resistance | ≥ 100 MΩ |
| Material of grip body | Zinc die-cast, nickel-plated |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Thickness, insulation | 0.21 mm (Core insulation) |
| Nominal voltage, cable | 300 V |
| Rated current at 40°C | 2 A |
| Conductor cross section | 0.25 mm² |
| Contact carrier material | PA 66 |
| Contact surface material | Ni/Au |
| Insertion/withdrawal cycles | > 100 |
| Material conductor insulation | TPE |
| Ambient temperature (operation) | -25 °C ... 85 °C (Plug / socket) |
| Conductor structure signal line | 14x 0.15 mm |
| Core diameter including insulation | 1.2 mm ±0.07 mm |
| Flammability rating according to UL 94 | V0 |