| Parameter | Value |
|---|---|
| GTIN | 4046356944632 |
| Orderkey | 1411893 |
| (Drawings) | |
| Packing unit | 1 |
| (Dimensions) | The connector pin assignment can be rotated 90° to the cable outlet |
| ETIM 4.0 (eCl@ss) | EC002635 |
| ETIM 5.0 (eCl@ss) | EC002635 |
| ETIM 6.0 (eCl@ss) | EC002061 |
| Note (Dimensions) | NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties. |
| UNSPSC 13.2 (ETIM) | 39121413 |
| UNSPSC 18.0 (ETIM) | 39121413 |
| UNSPSC 19.0 (ETIM) | 39121413 |
| UNSPSC 20.0 (ETIM) | 39121413 |
| UNSPSC 21.0 (ETIM) | 39121413 |
| Coding (Dimensions) | A - standard |
| Torque (Dimensions) | 0.4 Nm (M12 knurl) |
| Custom tariff number | 85366990 |
| Contact material (General) | CuZn |
| Material, knurls (General) | Zinc die-cast, nickel-plated |
| Rated voltage (Dimensions) | 60 V DC |
| Sealing material (General) | NBR |
| Status display (Dimensions) | No |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| eCl@ss 4.0 (Classifications) | 27260700 |
| eCl@ss 4.1 (Classifications) | 27260700 |
| eCl@ss 5.0 (Classifications) | 27260700 |
| eCl@ss 5.1 (Classifications) | 27260700 |
| eCl@ss 6.0 (Classifications) | 27260700 |
| eCl@ss 7.0 (Classifications) | 27440102 |
| eCl@ss 8.0 (Classifications) | 27440102 |
| eCl@ss 9.0 (Classifications) | 27440102 |
| Functional drawing (Drawings) | |
| Connection method (Dimensions) | Screw connection |
| Tightening torque (Dimensions) | Screw plug insert with sleeve housing as far it will go |
| Material of grip body (General) | Zinc die-cast, nickel-plated |
| eCl@ss 10.0.1 (Classifications) | 27440102 |
| Degree of pollution (Dimensions) | 3 |
| Number of positions (Dimensions) | 5 |
| Standards/specifications (Cable) | M12 connector IEC 61076-2-101 |
| Overvoltage category (Dimensions) | II |
| Assembly instructions (Dimensions) | The wires can be connected both with ferrules and without ferrules |
| Contact carrier material (General) | PA |
| Contact surface material (General) | Au |
| External cable diameter (Drawings) | 6 mm ... 8 mm |
| Insulation resistance (Dimensions) | ≥ 100 MΩ |
| Standards/regulations (Dimensions) | M12 connector IEC 61076-2-101 |
| Rated current at 40°C (Dimensions) | 4 A |
| Standards/specifications (Material) | M12 connector IEC 61076-2-101 |
| Conductor cross section (Dimensions) | 0.25 mm² ... 0.75 mm² |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Conductor cross section AWG (Dimensions) | 24 ... 18 |
| Connection in acc. with standard (Cable) | CUL |
| Insertion/withdrawal cycles (Dimensions) | ≥ 50 |
| Stripping length of the sheath (Drawings) | 40 mm |
| Flammability rating according to UL 94 (Cable) | HB |
| Flammability rating according to UL 94 (General) | HB |
| Stripping length of the individual wire (Drawings) | 5 mm |
| Schematic diagramPin assignment M12 male connector, 5-pos., A-coded, male side (Drawings) |
Technical specifications and performance data
Installation and operation guide