| Parameter | Value |
|---|---|
| GTIN | 4055626240893 |
| Orderkey | 1420753 |
| (General) | NBR (Cable clamping) |
| Packing unit | 1 |
| Custom tariff number | 85366990 |
| (Ambient conditions) | 0.2 Nm (Screw terminal blocks) |
| Note (Ambient conditions) | Strip 22 mm off the cable sheath, strip 7 mm off the conductor insulation, crimp the ferrule, then shorten this to 5 mm. Length of conductor with shortened ferrule: 20 mm. Connect conductors and tighten the mounting screws with 0.2 Nm. |
| Contact material (General) | CuZn |
| Material, knurls (General) | Zinc die-cast, nickel-plated |
| Sealing material (General) | Viton (M12 socket) |
| Coding (Ambient conditions) | A - standard |
| Torque (Ambient conditions) | 0.4 Nm (M12 knurl) |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Length (Key Commercial Data) | 54 mm |
| Standard designation (Cable) | M12 connector |
| eCl@ss 5.1 (Classifications) | 27260700 |
| eCl@ss 6.0 (Classifications) | 27260700 |
| eCl@ss 7.0 (Classifications) | 27440102 |
| eCl@ss 8.0 (Classifications) | 27440102 |
| eCl@ss 9.0 (Classifications) | 27440102 |
| Standards/regulations (Cable) | IEC 61076-2-101 |
| Material of grip body (General) | PA |
| Degree of protection (Dimensions) | IP67 |
| Contact carrier material (General) | PA |
| Contact surface material (General) | Au |
| Rated voltage (Ambient conditions) | 250 V DC |
| Standards/specifications (Material) | M12 connector IEC 61076-2-101 |
| Status display (Ambient conditions) | No |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Connection method (Ambient conditions) | Screw connection |
| REACh SVHC (Standards and Regulations) | |
| Degree of pollution (Ambient conditions) | 3 |
| Number of positions (Ambient conditions) | 4 |
| Overvoltage category (Ambient conditions) | II |
| Assembly instructions (Ambient conditions) | The wires can be connected both with ferrules and without ferrules |
| Insulation resistance (Ambient conditions) | > 10 GΩ |
| Standards/regulations (Ambient conditions) | M12 connector IEC 61076-2-101 |
| Rated current at 40°C (Ambient conditions) | 8 A |
| Conductor cross section (Ambient conditions) | 1.5 mm² |
| External cable diameter (Key Commercial Data) | 6 mm ... 8 mm |
| Flammability rating according to UL 94 (Cable) | V0 |
| Conductor cross section AWG (Ambient conditions) | 16 |
| Flammability rating according to UL 94 (General) | V0 |
| Insertion/withdrawal cycles (Ambient conditions) | ≥ 100 |
Technical specifications and performance data