

| Parameter | Value |
|---|---|
| GTIN | 4063151135249 |
| Orderkey | 1144971 |
| (Drawings) | |
| Packing unit | 1 |
| (Dimensions) | IP67 |
| Length (Drawings) | 43.4 mm |
| Custom tariff number | 85366990 |
| (Ambient conditions) | 0.2 Nm (M8 knurl) |
| Note (Ambient conditions) | NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties. |
| Contact material (General) | CuSn |
| Material, knurls (General) | Nickel-plated brass |
| Sealing material (General) | NBR |
| Coding (Ambient conditions) | A - standard |
| Diameter housing (Drawings) | 12.5 mm |
| Torque (Ambient conditions) | 0.6 Nm (Pressure nut) |
| Functional drawing (Drawings) | |
| Material of grip body (General) | PA 6 |
| Standards/specifications (Cable) | M8 connector IEC 61076-2-104 |
| Degree of protection (Dimensions) | IP65 |
| Contact carrier material (General) | TPU GF |
| Contact surface material (General) | Ni/Au |
| External cable diameter (Drawings) | 2.5 mm ... 5 mm ±0.2 mm |
| Rated voltage (Ambient conditions) | 30 V AC |
| Standards/specifications (Material) | M8 connector IEC 61076-2-104 |
| Status display (Ambient conditions) | No |
| Color handle area (Ambient conditions) | black |
| Connection method (Ambient conditions) | Insulation displacement connection |
| Degree of pollution (Ambient conditions) | 3 |
| Number of positions (Ambient conditions) | 4 |
| Overvoltage category (Ambient conditions) | II |
| Signal type/category (Ambient conditions) | Universal |
| Stripping length of the sheath (Drawings) | 40 mm |
| Insulation resistance (Ambient conditions) | ≥ 100 MΩ |
| Standards/regulations (Ambient conditions) | M8 connector IEC 61076-2-104 |
| Rated current at 40°C (Ambient conditions) | 4 A |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 80 °C (Plug / socket) |
| Conductor cross section (Ambient conditions) | 0.25 mm² ... 0.5 mm² |
| Wire insulation material (Ambient conditions) | PVC / PE / PP / rubber |
| Flammability rating according to UL 94 (Cable) | HB |
| Conductor cross section AWG (Ambient conditions) | 24 ... 20 |
| Flammability rating according to UL 94 (General) | HB |
| Insertion/withdrawal cycles (Ambient conditions) | ≥ 100 |
| Wire diameter including insulation (Ambient conditions) | 1.1 mm ... 1.55 mm |
| Frequency of connections between conductors of the same cross section (Ambient conditions) | 10 |
| Structure of individual litz in acc. with VDE 0295 / smallest wire diameter (Ambient conditions) | Class 2-6 |
Technical specifications and performance data
Installation and operation guide