| Parameter | Value |
|---|---|
| GTIN | 4055626673516 |
| Orderkey | 1051347 |
| (Drawings) | |
| Packing unit | 1 |
| ETIM 5.0 (eCl@ss) | EC002061 |
| ETIM 6.0 (eCl@ss) | EC002061 |
| (Connection data) | • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). |
| Custom tariff number | 85444290 |
| Cable type (Material) | UL/cUL stranded hook-up wire |
| Contact material (General) | CuZn |
| Coding (Ambient conditions) | S power |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Connection method (Material) | Individual wires |
| Current (Ambient conditions) | 12 A |
| Voltage (Ambient conditions) | 630 V |
| eCl@ss 8.0 (Classifications) | 27440103 |
| eCl@ss 9.0 (Classifications) | 27440102 |
| Fixed cable length (Drawings) | 2.5 |
| Safety note (Connection data) | WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. |
| Halogen-free (Connection data) | yes |
| eCl@ss 10.0.1 (Classifications) | 27440102 |
| Thread type (Ambient conditions) | M16 x 1.5 |
| Contact surface material (General) | Au |
| DiagramDerating diagram (Drawings) | |
| Flame resistance (Connection data) | in acc. to UL 1581 VW1 |
| Mounting type (Ambient conditions) | Rear mounting |
| AWG signal line (Ambient conditions) | 16 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Cable cross section (Ambient conditions) | 1.31 |
| Degree of pollution (Ambient conditions) | 3 |
| Number of positions (Ambient conditions) | 3 |
| Rated surge voltage (Ambient conditions) | 6 kV AC |
| Degree of protection (Ambient conditions) | IP67 |
| Overvoltage category (Ambient conditions) | III |
| Standards/regulations (Ambient conditions) | M12 connector In line with |
| Standards/specifications (Connection data) | M12 connector In line with |
| Tightening torque nut (Ambient conditions) | 3 Nm ... 4 Nm (M12 connector) |
| Ambient temperature (operation) (Dimensions) | -25 ... -85 (Plug / socket) |
| Flammability rating according to UL 94 (General) | V0 |
| Insertion/withdrawal cycles (Ambient conditions) | > 100 |
| Contact resistance with connected conductor (Material) | ≤ 3 mΩ |
| Flammability rating according to UL 94 (Connection data) | V0 |
| Circuit diagramContact assignment of the M12 plug (Drawings) |
Technical specifications and performance data
Installation and operation guide