| Parameter | Value |
|---|---|
| • WARNING: Serve only products in perfect condition. Products should be checked regularly for damage. Remove defective products immediately. Replace damaged products. It is not possible to repair them. | |
| Shielded | No |
| Cable type | TPE braided yarn |
| Plug Cycles | > 100 |
| Sensor Type | Universal |
| Cable length | 0.5 m |
| Codification | to |
| Line Section | 0.34 mm² |
| Product Type | Circular connectors (equipment side) |
| Safety Notes | WARNING: Connectors should not be plugged in or unplugged under load. Failure to comply and improper use can result in property damage and personal injury. |
| Surge Category | Ii |
| AWG Signal Line | 22 |
| Connection type | Single braided threads |
| Gasket material | FKM |
| Line Resistance | ≤ 57.6 mΩ/m |
| Number of poles | 5 |
| Contact material | CuZn |
| Protection Index | IP67 (In plugged in state) |
| Rules/Provisions | IEC 61076-2-101 |
| Type of mounting | Rear wall mount |
| Tightening torque | 3 Nm ... 4 Nm (on the mounting side) |
| Contact resistance | ≤ 3 mΩ |
| Header thread type | M12 |
| Nominal Current IN | 4 A |
| Nominal voltage UN | 60 V |
| Test Voltage Cable | 2000 V AC |
| Conductive Material | Tinned Cu Conductor |
| Degree of pollution | 3 |
| Header construction | Male connector |
| Signal Type/Category | Universal |
| Single Driver, Color | black, brown, blue, white, gray |
| Insulation resistance | ≥ 100 MΩ |
| Nominal Voltage Cable | 300 V |
| Number of Cable Outlets | 1 |
| Contact Support Material | AP 6.6 |
| Denomination of standard | M12 connector |
| Installation instructions | with flat nut |
| Material: Contact Surface | Au |
| Max. Conductor Resistance | 57.6 mΩ/m |
| Screw connection material | Zinc die-cast iron, nickel-plated |
| Wall Thickness Insulation | 0.21 mm (Conductor Insulation) |
| Line Insulation Resistance | ≥ 20 MΩ*km |
| Ambient Temperature (Service) | -40 °C ... 85°C (cable, fixed arrangement) |
| Dimensioning Transient Voltage | 1.5 kV |
| Material: Conductor Insulation | TPE |
| Conductor Construction Signal Cable | 7x 0.25 mm |
| Conductor diameter incl. insulation | 1.2 mm ±0.07 mm |
| Observation regarding the operation | The electrical and mechanical values listed require a pair of plug-in connectors that are properly assembled and locked. If the plug-in connector is unlocked and there is a danger of contamination, the plug-in connector must be closed with a cap > IP54. In addition, influences by conductors, lines, or assembly of printed circuit boards must be considered. |
| Flammability class according to UL 94 | V0 |