| Parameter | Value |
|---|---|
| 60 V DC | |
| Coding | A |
| General | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Shielded | no |
| Application | Signal |
| Head design | Pin |
| Thread type | M8 |
| Product type | Contact insert |
| Seal present | yes |
| Mounting type | PCB mounting |
| Seal material | FKM |
| Delivery state | with assembly pad |
| Contact material | CuZn |
| Head thread type | M8 |
| Connection method | SMD reflow |
| Cross section AWG | (converted acc. to IEC) |
| Head cable outlet | straight |
| Type of packaging | Belt |
| Contact resistance | ≤ 3 mΩ |
| Nominal current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Number of positions | 3 |
| Degree of protection | IP67 |
| Overvoltage category | III |
| Standard designation | M8 connector |
| Insulation resistance | ≤ 100 MΩ |
| Contact carrier material | PA |
| Contact surface material | Au |
| Standards/specifications | IEC 61076-2-104 |
| Insertion/withdrawal cycles | > 100 |
| Ambient temperature (operation) | -40 °C ... 105 °C (Plug / socket) |
| Degree of protection (when plugged in) | IP67 (correctly plugged in and locked) |
| Flammability rating according to UL 94 | V0 |