| Parameter | Value |
|---|---|
| -40 °C ... 105 °C (without mechanical actuation) | |
| Note | In line with |
| Coding | A |
| General | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Shielded | no |
| Application | Signal |
| Head design | Socket |
| Thread type | M12 |
| Product type | Contact insert |
| Seal present | yes |
| Mounting type | PCB mounting |
| Seal material | FKM |
| Contact material | CuZn |
| Head thread type | M12 |
| Connection method | SMD reflow |
| Cross section AWG | (converted acc. to IEC) |
| Head cable outlet | straight |
| Type of packaging | Tray |
| Contact resistance | ≤ 3 mΩ |
| Nominal current IN | 4 A |
| Nominal voltage UN | 250 V |
| Degree of pollution | 3 |
| Number of positions | 4 |
| Rated surge voltage | 2.5 kV |
| Degree of protection | IP67 |
| Overvoltage category | II |
| Standard designation | M12 connector |
| Insulation resistance | ≥ 100 MΩ |
| Contact carrier material | PA |
| Contact surface material | Au |
| Standards/specifications | IEC 61076-2-101 |
| Insertion/withdrawal cycles | > 100 |
| Ambient temperature (operation) | -25 °C ... 105 °C (Plug / socket) |
| Degree of protection (when plugged in) | IP67 (correctly plugged in and locked) |
| Flammability rating according to UL 94 | V0 |
Technical specifications and performance data