| Parameter | Value |
|---|---|
| GTIN | 4055626008288 |
| Note | Made to Order (non-returnable) |
| Orderkey | 1413558 |
| (Material) | -25 °C ... 85 °C (cable, flexible installation) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| Custom tariff number | 85366990 |
| (Key Commercial Data) | -40 °C ... 85 °C (without mechanical actuation) |
| Contact material (General) | CuZn |
| Sealing material (General) | FKM / EPDM |
| Coding (Ambient conditions) | A - standard |
| Torque (Ambient conditions) | 3 Nm ... 4 Nm (Installation-side) |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Standard designation (Cable) | M12 connector |
| Standards/regulations (Cable) | IEC 61076-2-101 |
| Contact carrier material (General) | PPA |
| Contact surface material (General) | Au |
| Mounting type (Ambient conditions) | PCB mounting |
| Rated voltage (Ambient conditions) | 60 V |
| Standards/specifications (Material) | M12 connector IEC 61076-2-101 |
| Status display (Ambient conditions) | No |
| Weight per Piece (excluding packing) | 5.000 g |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Connection method (Ambient conditions) | THR solder connection |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Degree of pollution (Ambient conditions) | 3 |
| Number of positions (Ambient conditions) | 5 |
| Rated surge voltage (Ambient conditions) | 1.5 kV |
| Overvoltage category (Ambient conditions) | II |
| Ambient temperature (operation) (Material) | -40 °C ... 85 °C (cable, fixed installation) |
| Degree of protection (Key Commercial Data) | IP67 |
| Insulation resistance (Ambient conditions) | ≥ 100 MΩ |
| Standards/regulations (Ambient conditions) | M12 connector IEC 61076-2-101 |
| Rated current at 40°C (Ambient conditions) | 4 A |
| Flammability rating according to UL 94 (Cable) | V0 |
| Flammability rating according to UL 94 (General) | V0 |
| Insertion/withdrawal cycles (Ambient conditions) | > 100 |
| Ambient temperature (operation) (Key Commercial Data) | -25 °C ... 85 °C (Plug / socket) |