| Parameter | Value |
|---|---|
| GTIN | 4063151130329 |
| Orderkey | 1143069 |
| (General) | |
| (Drawings) | 120 V DC |
| Packing unit | 1 |
| Note (Drawings) | NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties. |
| REACh SVHC (Cable) | Lead 7439-92-1 |
| Custom tariff number | 85444290 |
| (Insulation material) | -5 °C ... 80 °C (cable, flexible installation) |
| Rated voltage (Drawings) | 120 V AC |
| Number of slots (Drawings) | 4 |
| Degree of protection (General) | IP65 |
| Dimensional drawing (Drawings) | |
| Total rated current (Drawings) | 10 A |
| Cable type (Insulation material) | PUR/PVC black |
| Wire colors (Insulation material) | brown, blue, green/yellow, white, green, yellow, gray, gray/pink, red/blue, white/green, brown/green |
| Cable weight (Insulation material) | 122 kg/km |
| UL AWM style (Insulation material) | 20549 |
| Overall twist (Insulation material) | Wires twisted in layers |
| Bending radius (Insulation material) | 87 mm |
| Length of cable (Ambient conditions) | 25 m |
| AWG signal line (Insulation material) | 20 |
| Traversing path (Insulation material) | 2 m |
| Traversing rate (Insulation material) | 2 m/s |
| AWG power supply (Insulation material) | 17 |
| Connection method (Ambient conditions) | Pluggable screw connection |
| Flame resistance (Insulation material) | DIN EN 50265 |
| Other resistance (Insulation material) | Highly resistant to acids, alkaline solutions and solvents |
| Resistance to oil (Insulation material) | according to VDE 0472 Part 803 |
| Cable abbreviation (Insulation material) | LiYY11Y-HF |
| Conductor material (Insulation material) | Bare Cu litz wires |
| Special properties (Insulation material) | Silicone-free |
| Ambient temperature (operation) (General) | -25 °C ... 80 °C |
| Test voltage, cable (Insulation material) | 2000 V |
| External sheath, color (Insulation material) | black RAL 9005 |
| Inner sheath thickness (Insulation material) | ≥ 0.15 mm |
| Material, inner sheath (Insulation material) | PVC |
| Nominal voltage, cable (Insulation material) | 300 V |
| Outer sheath thickness (Insulation material) | ≥ 0.38 mm |
| Outer sheath, material (Insulation material) | PUR |
| Conductor cross section (Insulation material) | 8x 0.5 mm² (Signal line) |
| Current carrying capacity per slot (Drawings) | 4 A |
| Number of bending cycles (Insulation material) | 1500000 |
| Cable type (abbreviation) (Insulation material) | PUR |
| External cable diameter D (Insulation material) | 8.7 mm ±0.2 mm |
| Housing material (Master cable connection data) | PBT |
| Sealing material (Master cable connection data) | NBR |
| Current carrying capacity per I/O signal (Drawings) | 2 A |
| Material conductor insulation (Insulation material) | PVC |
| Ambient temperature (operation) (Insulation material) | -40 °C ... 90 °C (cable, fixed installation) |
| Conductor structure signal line (Insulation material) | 28x 0.15 mm |
| Core diameter including insulation (Insulation material) | 1.5 mm ±0.1 mm (Signal line) |
| Conductor structure, voltage supply (Insulation material) | 56x 0.15 mm |
| Minimum bending radius, fixed installation (Insulation material) | 7.5 x D |
| Minimum bending radius, flexible installation (Insulation material) | 10 x D |
| Material of contact, master cable side (Master cable connection data) | CU alloy |
| Material of contact surface, master cable side (Master cable connection data) | Sn |
| Material of the contact carrier on the master cable side (Master cable connection data) | PA |
Technical specifications and performance data