| Parameter | Value |
|---|---|
| 120 V DC | |
| LED | no |
| Width | 58 mm |
| Height | 21 mm |
| Length | 34 mm |
| Shielded | no |
| Cable type | PUR/PVC black [PUR] |
| Application | Sensor/actuator box |
| Cable length | 10 m |
| Cable weight | 77.9 kg/km |
| Product type | Connector hood |
| Test voltage | 2000 V |
| UL AWM Style | 20549 |
| Assembly note | NOTE:Observe the permissible bending radii when routing cables, since the degree of protection may be at risk if the bending forces are too high. Reduce mechanical loads upstream of the connector, e.g., by using cable ties. |
| Overall twist | Wires twisted in layers |
| AWG signal line | 22 |
| Number of slots | 4 |
| Flame resistance | DIN EN 50265 |
| Material Housing | PBT |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Connection method | Pluggable screw connection |
| Resistance to oil | according to VDE 0472 Part 803 |
| Conductor material | Bare Cu litz wires |
| Nominal voltage UN | 120 V AC |
| Single wire, color | brown, blue, green/yellow, white, green, yellow, gray |
| Special properties | Silicone-free |
| Dimensional drawing | |
| Number of positions | 7 |
| Degree of protection | IP65 |
| Rated current, total | 10 A |
| External sheath, color | black RAL 9005 |
| Inner sheath thickness | ≥ 0.15 mm |
| Nominal voltage, cable | 300 V |
| Outer sheath, material | PUR |
| Status display present | No |
| Conductor cross section | 4x 0.34 mm² (Signal line) |
| External cable diameter | 6.90 mm ±0.2 mm |
| Thickness, outer sheath | ≥ 0.38 mm |
| Material wire insulation | PVC |
| Tightening torque, cover screw | 0.35 Nm |
| Wire diameter incl. insulation | 1.3 mm ±0.1 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 90 °C (cable, fixed installation) |
| Conductor structure signal line | 19x 0.15 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 1500000, Bending radius: 69 mm, Traversing path: 2 m, Traversing rate: 2 m/s |
| Sensor/actuator connection system | M12-SPEEDCON-socket |
| Current carrying capacity per slot | 4 A |
| Material of contact, master cable side | CU alloy |
| Max. current carrying capacity per path | 2 A |
| Slot/position = Wire color or connection | 1 / 4 (A) = WH |
| Minimum bending radius, fixed installation | 7.5 x D |
| Smallest bending radius, fixed installation | 52 mm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 69 mm |
| Material of contact surface, master cable side | gold-plated |
| Material of the contact carrier on the master cable side | PA |