| Parameter | Value |
|---|---|
| PBT | |
| Coding | A |
| General | NOTE:Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties. |
| Material | PBT |
| Shielded | no |
| Cable type | PUR/PVC black |
| Application | Standard |
| Cable length | 40 m |
| Cable weight | 107.4 kg/km |
| Product type | Distributor boxes with M8 to M12 slots |
| Short symbol | LiYY11Y-HF |
| UL AWM Style | 20549 (80°C/300 V) |
| Overall twist | Wires twisted in layers |
| AWG signal line | 22 |
| Number of slots | 8 |
| Traversing path | 2 m |
| Traversing rate | 2 m/s |
| AWG power supply | 18 |
| Cable resistance | ≤ 53 Ω/km (Signal line) |
| Contact material | Cu alloy |
| Flame resistance | DIN EN 50265 |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Connection method | Fixed connection |
| Resistance to oil | according to VDE 0472 Part 803 |
| Conductor material | Bare Cu litz wires |
| Nominal voltage UN | 24 V DC |
| Single wire, color | brown, blue, green/yellow, white, green, yellow, gray, pink, red, black, violet |
| Special properties | Silicone-free |
| Dimensional drawing | |
| Number of positions | 4 |
| Degree of protection | IP65 |
| Rated current, total | 12 A |
| Seal material O-ring | NBR |
| Standard designation | M12 connector |
| External sheath, color | black RAL 9005 |
| Inner sheath thickness | ≥ 0.15 mm |
| Material, inner sheath | PVC |
| Nominal voltage, cable | 300 V AC |
| Outer sheath, material | PUR |
| Status display present | Yes |
| Test voltage Core/Core | 2000 V (50 Hz, 5 min.) |
| Conductor cross section | 8x 0.34 mm² (Signal line) |
| External cable diameter | 8.5 mm ±0.2 mm |
| Thickness, outer sheath | ≥ 0.38 mm |
| Contact carrier material | PA |
| Contact surface material | gold-plated |
| Material wire insulation | PVC |
| Number of bending cycles | 1500000 |
| Standards/specifications | IEC 61076-2-101 |
| Cable type (abbreviation) | PUR |
| Cable insulation resistance | ≥ 5 MΩ*km |
| Max. operating voltage Umax | 30 V DC |
| Wire diameter incl. insulation | 1.3 mm ±0.1 mm (Signal line) |
| Ambient temperature (operation) | -5 °C ... 80 °C (Cable, flexible installation) |
| Conductor structure signal line | 19x 0.15 mm |
| Current carrying capacity per slot | 4 A |
| Conductor structure, voltage supply | 42x 0.15 mm |
| Flammability rating according to UL 94 | V0 |
| Max. current carrying capacity per path | 2 A |
| Minimum bending radius, fixed installation | 7.5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Minimum bending radius, drag chain applications | 10 x D |
Technical specifications and performance data