Service time: Monday to Friday 9:00-18:00
SACB- 8/3-L-1,5PUR-M8 - SACB- 8/3-L-1,5PUR-M8 1030880 PHOENIX CONTACT Sensor/actuator box
In Stock Hot Product

SACB- 8/3-L-1,5PUR-M8

SACB- 8/3-L-1,5PUR-M8 1030880 PHOENIX CONTACT Sensor/actuator box

$0.00USD
4867 in stock
Key Specifications
GTIN:4055626534718
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1030880
(General):IP67
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626534718
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1030880
(General)IP67
Packing unit1
China RoHS (Cable)Environmentally Friendly Use Period = 50
Custom tariff number85444290
(Standards and Regulations)-5 °C ... 80 °C (cable, flexible installation)
Degree of protection (General)IP65
Rated voltage (Key Commercial Data)24 V DC
Number of slots (Key Commercial Data)8
Cable type (Standards and Regulations)PUR/PVC black
Local diagnostics (Ambient conditions)Supply voltage Green LED
Wire colors (Standards and Regulations)brown, blue, white, green, yellow, gray, pink, red, black, violet
Cable weight (Standards and Regulations)92 kg/km
UL AWM style (Standards and Regulations)20549
Ambient temperature (operation) (General)-30 °C ... 80 °C
Number of positions (Key Commercial Data)3
Overall twist (Standards and Regulations)Wires twisted in layers
Total rated current (Key Commercial Data)6 A
Bending radius (Standards and Regulations)79 mm
Standard designation (Insulation material)M8 connector
AWG signal line (Standards and Regulations)22
Standards/regulations (Insulation material)IEC 61076-2-104
Traversing path (Standards and Regulations)2 m
Traversing rate (Standards and Regulations)2 m/s
AWG power supply (Standards and Regulations)18
Flame resistance (Standards and Regulations)DIN EN 50265
Length of cable (Local diagnostics function)1.5 m
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations)according to VDE 0472 Part 803
Cable abbreviation (Standards and Regulations)LiYY11Y-HF
Conductor material (Standards and Regulations)Bare Cu litz wires
Connection method (Local diagnostics function)Fixed connection
O-ring material (Master cable connection data)NBR
Special properties (Standards and Regulations)Silicone-free
Contact material (Master cable connection data)CuSn
Housing material (Master cable connection data)PBT
Test voltage, cable (Standards and Regulations)2000 V
Max. operating voltage Umax (Key Commercial Data)30 V DC
External sheath, color (Standards and Regulations)black RAL 9005
Inner sheath thickness (Standards and Regulations)≥ 0.15 mm
Material, inner sheath (Standards and Regulations)PVC
Nominal voltage, cable (Standards and Regulations)300 V
Outer sheath thickness (Standards and Regulations)≥ 0.38 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)8x 0.34 mm² (Signal line)
Number of bending cycles (Standards and Regulations)1500000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)7.9 mm ±0.2 mm
Contact carrier material (Master cable connection data)PA
Contact surface material (Master cable connection data)Ni/Au
Current carrying capacity per slot (Key Commercial Data)2 A
Material conductor insulation (Standards and Regulations)PVC
Material of threaded sleeve (Master cable connection data)Cu alloy
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 90 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)19x 0.15 mm
Flammability rating according to UL 94 (Insulation material)V0
Flammability rating according to UL 94 (Key Commercial Data)V0
Material of the moulding mass (Master cable connection data)PUR
Core diameter including insulation (Standards and Regulations)1.3 mm ±0.1 mm (Signal line)
Current carrying capacity per I/O signal (Key Commercial Data)2 A
Conductor structure, voltage supply (Standards and Regulations)42x 0.15 mm
Material of threaded sleeve surface (Master cable connection data)Nickel-plated
Minimum bending radius, fixed installation (Standards and Regulations)7.5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Tightening torque slot sensor/actuator cable (Local diagnostics function)0.2 Nm

Product Description

Sensor/actuator box, application: Standard, number of plug-in stations: 8, number of poles: 3, coding: A - standard, occupation of plug-in stations: simple, status indication: Yes, pnp; Main cable con
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top