| Parameter | Value |
|---|---|
| GTIN | 4046356536110 |
| Note | Made to Order (non-returnable) |
| (Cable) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Orderkey | 1401199 |
| (General) | -5 °C ... 80 °C (cable, flexible installation) |
| Catalog page | Page 167 (C-4-2013) |
| Packing unit | 1 pc |
| Country of origin | PL (Poland) |
| China RoHS (Cable) | Environmentally Friendly Use Period = 50 |
| Custom tariff number | 85444290 |
| (Insulation material) | 1-8 / 5 (PE) = GN/YE |
| (Standards and Regulations) | 5 °C ... 70 °C (cable, flexible installation) |
| Degree of protection (General) | IP65 |
| Rated voltage (Key Commercial Data) | 24 V DC |
| Length of cable (Ambient conditions) | 5 m |
| Weight per Piece (excluding packing) | 1,269.000 g |
| Number of slots (Key Commercial Data) | 8 |
| Standard designation (Pin assignment) | M12 connector |
| Cable type (Standards and Regulations) | PUR halogen-free, highly flexible |
| Connection method (Ambient conditions) | Fixed connection |
| Standards/regulations (Pin assignment) | IEC 61076-2-101 |
| Wire colors (Standards and Regulations) | brown, blue, green/yellow, white, green, yellow, gray, pink, red, black, violet, gray/pink, red/blue, white/green, brown/green, white/yellow, yellow/brown, white/gray, gray/brown |
| Acceleration (Standards and Regulations) | 5 m/s² |
| Halogen-free (Standards and Regulations) | The cable is halogen-free |
| Ambient temperature (operation) (General) | -30 °C ... 90 °C |
| Number of positions (Key Commercial Data) | 5 |
| Overall twist (Standards and Regulations) | Wires twisted to an optimum in two layers |
| Torsion force (Standards and Regulations) | ± 120 °/m (≥ 3 million torsion cycles) |
| Total rated current (Key Commercial Data) | 12 A |
| Bending radius (Standards and Regulations) | 120 mm |
| AWG signal line (Standards and Regulations) | 20 |
| Traversing path (Standards and Regulations) | 5 m |
| Traversing rate (Standards and Regulations) | 3 m/s |
| AWG power supply (Standards and Regulations) | 17 |
| Flame resistance (Standards and Regulations) | DIN EN 50265-2-1 |
| Other resistance (Standards and Regulations) | somewhat resistant to welding sparks |
| Resistance to oil (Standards and Regulations) | in accordance with DIN EN 60811-2-1 |
| Cable abbreviation (Standards and Regulations) | LS9Y11Y-J-EFK |
| Conductor material (Standards and Regulations) | Bare Cu litz wires |
| O-ring material (Master cable connection data) | NBR |
| Special properties (Standards and Regulations) | Silicone-free |
| Contact material (Master cable connection data) | Cu alloy |
| Housing material (Master cable connection data) | PBT |
| Test voltage, cable (Standards and Regulations) | 2000 V |
| Conductor resistance (Standards and Regulations) | 39 Ω/km (Signal line) |
| Insulation resistance (Standards and Regulations) | ≥ 10 MΩ*km (at 20 °C) |
| Max. operating voltage Umax (Key Commercial Data) | 30 V DC |
| External sheath, color (Standards and Regulations) | black RAL 9005 |
| Nominal voltage, cable (Standards and Regulations) | 300 V |
| Outer sheath, material (Standards and Regulations) | PUR |
| Conductor cross section (Standards and Regulations) | 16x 0.5 mm² (Signal line) |
| Number of bending cycles (Standards and Regulations) | 5000000 |
| Cable type (abbreviation) (Standards and Regulations) | 80MC |
| External cable diameter D (Standards and Regulations) | 10.75 mm |
| Contact carrier material (Master cable connection data) | PA |
| Contact surface material (Master cable connection data) | gold-plated |
| Flammability rating according to UL 94 (Pin assignment) | V0 |
| Sensor/actuator connection system (Key Commercial Data) | M12-SPEEDCON-socket |
| Current carrying capacity per slot (Key Commercial Data) | 4 A |
| Material conductor insulation (Standards and Regulations) | PP |
| Material of threaded sleeve (Master cable connection data) | Zinc die-cast |
| Ambient temperature (operation) (Standards and Regulations) | -30 °C ... 70 °C (cable, fixed installation) |
| Conductor structure signal line (Standards and Regulations) | 28x 0.15 mm |
| Flammability rating according to UL 94 (Key Commercial Data) | V0 |
| Material of the moulding mass (Master cable connection data) | PUR |
| Current carrying capacity per I/O signal (Key Commercial Data) | 2 A |
| Slot/position = Wire color or connection (Insulation material) | 1 / 4 (A) = WH |
| Conductor structure, voltage supply (Standards and Regulations) | 56x 0.15 mm |
| Tightening torque slot sensor/actuator cable (Ambient conditions) | 0.4 Nm |
| Material of threaded sleeve surface (Master cable connection data) | Nickel-plated |
| Smallest bending radius, fixed installation (Standards and Regulations) | 90 mm |
| Smallest bending radius, movable installation (Standards and Regulations) | 120 mm |
| Tightening torque of mounting screw for fixing the housing (Ambient conditions) | 0.5 Nm |
Technical specifications and performance data
Installation and operation guide