| Parameter | Value |
|---|---|
| 3x 1 mm² (power line) | |
| Coding | A |
| Shielded | no |
| Cable type | PUR/PVC black [PUR] |
| Application | Standard |
| Cable length | 0.2 m |
| Cable weight | 183.7 kg/km |
| Product type | Distributor box |
| Test voltage | 2000 V |
| UL AWM Style | 20549 (80°C/300 V) |
| Overall twist | Wires twisted in layers |
| AWG signal line | 20 |
| Number of slots | 8 |
| Contact material | Cu alloy |
| Flame resistance | according to DIN EN 50265 |
| Material Housing | PBT |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Resistance to oil | according to VDE 0472 Part 803 |
| Conductor material | Bare Cu litz wires |
| Nominal voltage UN | 24 V DC |
| Single wire, color | brown, blue, green/yellow, white, green, yellow, gray, pink, red, black, violet, gray/pink, red/blue, white/green, brown/green, white/yellow, yellow/brown, white/gray, gray/brown |
| Special properties | Silicone-free |
| Dimensional drawing | |
| Number of positions | 5 |
| Degree of protection | IP65 |
| Rated current, total | 12 A |
| Seal material O-ring | NBR |
| Standard designation | M12 connector |
| External sheath, color | black RAL 9005 |
| Inner sheath thickness | ≥ 0.15 mm |
| Nominal voltage, cable | 300 V |
| Outer sheath, material | PUR |
| Status display present | Yes |
| Conductor cross section | 16x 0.5 mm² (Signal line) |
| External cable diameter | 10.50 mm ±0.2 mm |
| Thickness, outer sheath | ≥ 0.76 mm |
| Contact carrier material | PA |
| Contact surface material | gold-plated |
| Material Threaded sleeve | Die-cast zinc |
| Material wire insulation | PVC |
| Standards/specifications | IEC 61076-2-101 |
| Material Molding compound | PUR |
| Max. operating voltage Umax | 30 V DC |
| Wire diameter incl. insulation | 1.5 mm ±0.1 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 90 °C (cable, fixed installation) |
| Conductor structure signal line | 28x 0.15 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 1500000, Bending radius: 10 x D, Traversing path: 2 m, Traversing rate: 2 m/s |
| Current carrying capacity per slot | 4 A |
| Flammability rating according to UL 94 | V0 |
| Max. current carrying capacity per path | 2 A |
| Minimum bending radius, fixed installation | 7.5 x D |
| Smallest bending radius, fixed installation | 79 mm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 105 mm |
Technical specifications and performance data
Installation and operation guide