Key Specifications
GTIN:4046356620833
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1457364
(General):-5 °C ... 80 °C (cable, flexible installation)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356620833
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1457364
(General)-5 °C ... 80 °C (cable, flexible installation)
Catalog pagePage 160 (C-4-2013)
Packing unit1 pc
Country of originPL (Poland)
China RoHS (Cable)Environmentally Friendly Use Period = 50
Custom tariff number85444290
(Insulation material)1-8 / 5 (PE) = GN/YE
(Key Commercial Data)
(Standards and Regulations)-5 °C ... 80 °C (cable, flexible installation)
Degree of protection (General)IP65
Rated voltage (Key Commercial Data)120 V
Length of cable (Ambient conditions)5 m
Weight per Piece (excluding packing)1,220.400 g
Number of slots (Key Commercial Data)8
Standard designation (Pin assignment)M12 connector
Cable type (Standards and Regulations)PUR/PVC black
Connection method (Ambient conditions)Fixed connection
Standards/regulations (Pin assignment)IEC 61076-2-101
Wire colors (Standards and Regulations)brown, blue, green/yellow, white, green, yellow, gray, pink, red, black, violet, gray/pink, red/blue, white/green, brown/green, white/yellow, yellow/brown, white/gray, gray/brown
Cable weight (Standards and Regulations)183.7 kg/km
UL AWM style (Standards and Regulations)20549 (80°C/300 V)
Ambient temperature (operation) (General)-30 °C ... 90 °C
Number of positions (Key Commercial Data)5
Overall twist (Standards and Regulations)Wires twisted in layers
Total rated current (Key Commercial Data)12 A
AWG signal line (Standards and Regulations)20
Traversing path (Standards and Regulations)2 m
Traversing rate (Standards and Regulations)2 m/s
AWG power supply (Standards and Regulations)17
Flame resistance (Standards and Regulations)according to DIN EN 50265
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations)according to VDE 0472 Part 803
Cable abbreviation (Standards and Regulations)LiYY11Y-HF
Conductor material (Standards and Regulations)Bare Cu litz wires
O-ring material (Master cable connection data)FPM
Special properties (Standards and Regulations)Silicone-free
Contact material (Master cable connection data)Cu alloy
Housing material (Master cable connection data)PBT
Test voltage, cable (Standards and Regulations)2000 V
Max. operating voltage Umax (Key Commercial Data)135 V
External sheath, color (Standards and Regulations)black RAL 9005
Inner sheath thickness (Standards and Regulations)≥ 0.15 mm
Material, inner sheath (Standards and Regulations)PVC
Nominal voltage, cable (Standards and Regulations)300 V
Outer sheath thickness (Standards and Regulations)≥ 0.76 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)16x 0.5 mm² (Signal line)
Number of bending cycles (Standards and Regulations)1500000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)10.5 mm ±0.2 mm
Contact carrier material (Master cable connection data)PA
Contact surface material (Master cable connection data)gold-plated
Sensor/actuator connection system (Key Commercial Data)M12 socket
Current carrying capacity per slot (Key Commercial Data)4 A
Material conductor insulation (Standards and Regulations)PVC
Material of threaded sleeve (Master cable connection data)Zinc die-cast
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 90 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)28x 0.15 mm
Material of the moulding mass (Master cable connection data)PUR
Core diameter including insulation (Standards and Regulations)1.5 mm ±0.1 mm (Signal line)
Current carrying capacity per I/O signal (Key Commercial Data)2 A
Slot/position = Wire color or connection (Insulation material)1 / 4 (A) = WH
Conductor structure, voltage supply (Standards and Regulations)56x 0.15 mm
Tightening torque slot sensor/actuator cable (Ambient conditions)0.4 Nm
Material of threaded sleeve surface (Master cable connection data)tin-plated
Minimum bending radius, fixed installation (Standards and Regulations)7.5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

Sensor/actuator box, application: Outdoor spaces, connection type: M12 Metal female connector, number of plug-in stations: 8, number of poles: 5, coding: A - standard, occupancy of plug-in stations: D
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top