| Parameter | Value |
|---|---|
| 2 / 4 (A) = GN | |
| LED | no |
| Width | 54 mm |
| Coding | A |
| Height | 23 mm |
| Length | 123 mm |
| Shielded | no |
| Cable type | PUR/PVC black [PUR] |
| Application | Standard |
| Cable length | 5 m |
| Cable weight | 96.6 kg/km |
| Product type | Distributor box |
| Test voltage | 2000 V |
| UL AWM Style | 20549 |
| Overall twist | Wires twisted in layers |
| AWG signal line | 22 |
| Number of slots | 6 |
| Contact material | Cu alloy |
| Flame resistance | DIN EN 50265 |
| Material Housing | PBT |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Resistance to oil | according to VDE 0472 Part 803 |
| Conductor material | Bare Cu litz wires |
| Nominal voltage UN | 120 V |
| Single wire, color | brown, blue, green/yellow, white, green, yellow, gray, pink, red |
| Special properties | Silicone-free |
| Dimensional drawing | |
| Number of positions | 4 |
| Degree of protection | IP65 |
| Rated current, total | 12 A |
| Seal material O-ring | NBR |
| Standard designation | M12 connector |
| Thickness, insulation | ≥ 0.15 mm (Inner sheath) |
| External sheath, color | black RAL 9005 |
| Nominal voltage, cable | 300 V |
| Outer sheath, material | PUR |
| Status display present | No |
| Conductor cross section | 6x 0.34 mm² (Signal line) |
| External cable diameter | 8.00 mm ±0.2 mm |
| Contact carrier material | PA |
| Contact surface material | gold-plated |
| Material Threaded sleeve | PBT |
| Material wire insulation | PVC |
| Standards/specifications | IEC 61076-2-101 |
| Material Molding compound | PUR |
| Wire diameter incl. insulation | 1.3 mm ±0.1 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 90 °C (cable, fixed installation) |
| Conductor structure signal line | 19x 0.15 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 1500000, Bending radius: 80 mm, Traversing path: 2 m, Traversing rate: 2 m/s |
| Sensor/actuator connection system | M12-SPEEDCON-socket |
| Current carrying capacity per slot | 4 A |
| Max. current carrying capacity per path | 2 A |
| Slot/position = Wire color or connection | 1 / 4 (A) = WH |
| Minimum bending radius, fixed installation | 7.5 x D |
| Smallest bending radius, fixed installation | 60 mm |
| Tightening torque slot sensor/actuator cable | 0.4 Nm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 80 mm |
| Tightening torque of mounting screw for fixing the housing | 0.5 Nm |
Technical specifications and performance data