| Parameter | Value |
|---|---|
| PBT | |
| Coding | A |
| General | NOTE:Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties. |
| Material | Die-cast zinc |
| Shielded | no |
| Cable type | PUR/PVC black |
| Application | Standard |
| Cable length | 40 m |
| Cable weight | 96.6 kg/km |
| Product type | Distributor boxes with M8 to M12 slots |
| Short symbol | LiYY11Y-HF |
| UL AWM Style | 20549 |
| Overall twist | Wires twisted in layers |
| Seal material | NBR |
| Bending radius | 80 mm |
| AWG signal line | 22 |
| Number of slots | 6 |
| Traversing path | 2 m |
| Traversing rate | 2 m/s |
| AWG power supply | 18 |
| Contact material | Cu alloy |
| Flame resistance | DIN EN 50265 |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Connection method | Fixed connection |
| Resistance to oil | according to VDE 0472 Part 803 |
| Conductor material | Bare Cu litz wires |
| Nominal voltage UN | 120 V AC |
| Single wire, color | brown, blue, green/yellow, white, green, yellow, gray, pink, red |
| Special properties | Silicone-free |
| Dimensional drawing | |
| Number of positions | 4 |
| Test voltage, cable | 2000 V |
| Degree of protection | IP65 |
| Rated current, total | 12 A |
| Standard designation | M12 connector |
| Thickness, insulation | ≥ 0.15 mm (Inner sheath) |
| External sheath, color | black RAL 9005 |
| Material, inner sheath | PVC |
| Nominal voltage, cable | 300 V |
| Outer sheath, material | PUR |
| Status display present | No |
| Conductor cross section | 6x 0.34 mm² (Signal line) |
| External cable diameter | 8 mm ±0.2 mm |
| Contact carrier material | PA |
| Contact surface material | gold-plated |
| Material wire insulation | PVC |
| Number of bending cycles | 1500000 |
| Standards/specifications | IEC 61076-2-101 |
| Cable type (abbreviation) | PUR |
| Max. operating voltage Umax | 135 V |
| Wire diameter incl. insulation | 1.3 mm ±0.1 mm (Signal line) |
| Ambient temperature (operation) | -5 °C ... 80 °C (Cable, flexible installation) |
| Conductor structure signal line | 19x 0.15 mm |
| Current carrying capacity per slot | 4 A |
| Conductor structure, voltage supply | 42x 0.15 mm |
| Flammability rating according to UL 94 | V0 |
| Max. current carrying capacity per path | 2 A |
| Minimum bending radius, fixed installation | 7.5 x D |
| Minimum bending radius, flexible installation | 10 x D |
Technical specifications and performance data