Service time: Monday to Friday 9:00-18:00
SACB-6/12-L-20,0PUR SCO P - SACB-6/12-L-20,0PUR SCO P 1146339 PHOENIX CONTACT Sensor/actuator box, application: Standard, number of slot..
In Stock Hot Product

SACB-6/12-L-20,0PUR SCO P

SACB-6/12-L-20,0PUR SCO P 1146339 PHOENIX CONTACT Sensor/actuator box, application: Standard, number of slot..

$0.00USD
4682 in stock
Key Specifications
GTIN:4063151137373
Orderkey:1146339
(General):-5 °C ... 80 °C (for flexible installation)
(Drawings):Unused slots are to be sealed off prior to commissioning. Suitable sealing elements are to be found under "Accessories".
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4063151137373
Orderkey1146339
(General)-5 °C ... 80 °C (for flexible installation)
(Drawings)Unused slots are to be sealed off prior to commissioning. Suitable sealing elements are to be found under "Accessories".
Packing unit1
Note (Drawings)NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.
Custom tariff number85444290
(Ambient conditions)Status display I/O Yellow LED
(Insulation material)1-6 / 5 (PE) = GN/YE
Rated voltage (Drawings)24 V DC
Number of slots (Drawings)6
(Standards and Regulations)-5 °C ... 80 °C (cable, flexible installation)
Degree of protection (General)IP65
Dimensional drawing (Drawings)
Number of positions (Drawings)5
Total rated current (Drawings)12 A
Cable type (Standards and Regulations)PUR/PVC black
Local diagnostics (Ambient conditions)Supply voltage Green LED
Max. operating voltage Umax (Drawings)30 V DC
Wire colors (Standards and Regulations)brown, blue, green/yellow, white, green, yellow, gray, pink, red, gray/pink, red/blue, white/green, brown/green, white/yellow, yellow/brown
Cable weight (Standards and Regulations)150.9 kg/km
UL AWM style (Standards and Regulations)20549
Ambient temperature (operation) (General)-25 °C ... 80 °C
Overall twist (Standards and Regulations)Wires twisted in layers
Standards/specifications (Pin assignment)M12 connector IEC 61076-2-101
Bending radius (Standards and Regulations)94 mm
AWG signal line (Standards and Regulations)20
Traversing path (Standards and Regulations)2 m
Traversing rate (Standards and Regulations)2 m/s
AWG power supply (Standards and Regulations)17
Flame resistance (Standards and Regulations)DIN EN 50265
Length of cable (Local diagnostics function)20 m
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Current carrying capacity per slot (Drawings)4 A
Resistance to oil (Standards and Regulations)according to VDE 0472 Part 803
Cable abbreviation (Standards and Regulations)LiYY11Y-HF
Conductor material (Standards and Regulations)Bare Cu litz wires
Connection method (Local diagnostics function)Fixed connection
O-ring material (Master cable connection data)NBR
Special properties (Standards and Regulations)Silicone-free
Contact material (Master cable connection data)Cu alloy
Housing material (Master cable connection data)PBT
Test voltage, cable (Standards and Regulations)2000 V
Thickness, insulation (Standards and Regulations)≥ 0.15 mm (Inner sheath)
External sheath, color (Standards and Regulations)black RAL 9005
Material, inner sheath (Standards and Regulations)PVC
Nominal voltage, cable (Standards and Regulations)300 V
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)12x 0.5 mm² (Signal line)
Current carrying capacity per I/O signal (Drawings)2 A
Number of bending cycles (Standards and Regulations)1500000
Schematic diagramM12 slot, socket, 5-pos. (Drawings)
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)9.4 mm ±0.2 mm
Contact carrier material (Master cable connection data)PA
Contact surface material (Master cable connection data)gold-plated
Material conductor insulation (Standards and Regulations)PVC
Material of threaded sleeve (Master cable connection data)PBT
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 90 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)28x 0.15 mm
Material of the moulding mass (Master cable connection data)PUR
Core diameter including insulation (Standards and Regulations)1.5 mm ±0.1 mm (Signal line)
Slot/position = Wire color or connection (Insulation material)1 / 4 (A) = WH
Conductor structure, voltage supply (Standards and Regulations)56x 0.15 mm
Minimum bending radius, fixed installation (Standards and Regulations)7.5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Tightening torque slot sensor/actuator cable (Local diagnostics function)0.4 Nm
Tightening torque of mounting screw for fixing the housing (Local diagnostics function)0.5 Nm

Product Description

Sensor/actuator box, application: Standard, number of plug-in stations: 6, number of poles: 5, coding: A - standard, occupation of plug-in stations: Double, status indication: Yes, pnp; Main cable con
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawing

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top