| Parameter | Value |
|---|---|
| GTIN | 4017918170967 |
| Orderkey | 1683633 |
| (General) | IP67 |
| Catalog page | Page 273 (C-2-2017) |
| Packing unit | 1 pc |
| Country of origin | PL (Poland) |
| Custom tariff number | 85366990 |
| (Insulation material) | 1-4 / 5 (PE) = PE |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Degree of protection (General) | IP65 |
| Contact material (Conductor data) | Steel/copper |
| Housing material (Conductor data) | PA |
| Rated voltage (Key Commercial Data) | 120 V |
| Weight per Piece (excluding packing) | 162.000 g |
| Number of slots (Key Commercial Data) | 4 |
| Stripping length (Ambient conditions) | 70 mm (Master cable) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Connection method (Ambient conditions) | Spring-cage connection |
| Ambient temperature (operation) (General) | -25 °C ... 60 °C |
| Contact carrier material (Conductor data) | PA 6.6 |
| Contact surface material (Conductor data) | Sn |
| Number of positions (Key Commercial Data) | 4 |
| Total rated current (Key Commercial Data) | 12 A |
| Material of the moulding mass (Conductor data) | PUR |
| Stripping length (signal) (Ambient conditions) | 10 mm |
| Connection in acc. with standard (Pin assignment) | CUL |
| External cable diameter max. (Ambient conditions) | 9.5 mm |
| External cable diameter min. (Ambient conditions) | 6.5 mm |
| Max. operating voltage Umax (Key Commercial Data) | 135 V |
| Tightening torque, union nut (Ambient conditions) | 2.5 Nm |
| Flammability rating according to UL 94 (Pin assignment) | V0 |
| Material of contact, master cable side (Conductor data) | CuZn |
| Sensor/actuator connection system (Key Commercial Data) | QUICKON |
| Current carrying capacity per slot (Key Commercial Data) | 4 A |
| Conductor cross section max. (energy) (Ambient conditions) | 1.5 mm² |
| Conductor cross section max. (signal) (Ambient conditions) | 1 mm² |
| Conductor cross section min. (energy) (Ambient conditions) | 0.2 mm² |
| Conductor cross section min. (signal) (Ambient conditions) | 0.14 mm² |
| Wrench size, union nut (Master cable data/connection data) | 22 mm |
| Flammability rating according to UL 94 (Key Commercial Data) | V0 |
| Wire insulation material (Master cable data/connection data) | PVC / PE |
| Conductor cross section AWG max. (energy) (Ambient conditions) | 16 |
| Conductor cross section AWG max. (signal) (Ambient conditions) | 17 |
| Conductor cross section AWG min. (energy) (Ambient conditions) | 24 |
| Conductor cross section AWG min. (signal) (Ambient conditions) | 26 |
| Current carrying capacity per I/O signal (Key Commercial Data) | 4 A |
| Slot/position = Wire color or connection (Insulation material) | 1 / 4 (A) = 1 / 4 |
| Material of contact surface, master cable side (Conductor data) | NiSn |
| Tightening torque, union nut (Master cable data/connection data) | 2.5 Nm |
| Conductor cross section AWG max. (Master cable data/connection data) | 18 |
| Conductor cross section AWG min. (Master cable data/connection data) | 22 |
| Wire diameter including insulation (Master cable data/connection data) | ≤ 2.5 mm |
| Maximum external conductor diameter (Master cable data/connection data) | 7.5 mm |
| Minimum external conductor diameter (Master cable data/connection data) | 4 mm |
| Note on the frequency of connections (Master cable data/connection data) | if the conductor is connected more than once, seal and cap may need to be replaced. |
| Conductor cross section flexible max. (Master cable data/connection data) | 0.75 mm² |
| Conductor cross section flexible min. (Master cable data/connection data) | 0.34 mm² |
| Material of the contact carrier on the master cable side (Conductor data) | PA 6.6 V0 |
| Structure of individual litz in acc. with VDE 0295 / smallest wire diameter (Master cable data/connection data) | Class 2-6 // 0.34 mm²: 0.1 mm; 0.5 - 0.75 mm²: 0.15 mm |
Technical specifications and performance data