Service time: Monday to Friday 9:00-18:00
SACB-4/ 8-L-5,0PUR SCO - SACB-4/ 8-L-5,0PUR SCO 1517107 PHOENIX CONTACT Sensor/actuator box
In Stock Hot Product

SACB-4/ 8-L-5,0PUR SCO

SACB-4/ 8-L-5,0PUR SCO 1517107 PHOENIX CONTACT Sensor/actuator box

$125.01USD
119 in stock
Key Specifications
GTIN:4017918967772
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1517107
(General):-5 °C ... 80 °C (for flexible installation)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918967772
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1517107
(General)-5 °C ... 80 °C (for flexible installation)
Catalog pagePage 270 (C-2-2017)
Packing unit1 pc
Country of originPL (Poland)
China RoHS (Cable)Environmentally Friendly Use Period = 50
Custom tariff number85444290
(Ambient conditions)Status display I/O Yellow LED
(Insulation material)1-4 / 5 (PE) = GN/YE
(Standards and Regulations)-5 °C ... 80 °C (cable, flexible installation)
Degree of protection (General)IP65
Rated voltage (Key Commercial Data)24 V DC
Weight per Piece (excluding packing)869.300 g
Number of slots (Key Commercial Data)4
Standard designation (Pin assignment)M12 connector
Cable type (Standards and Regulations)PUR/PVC black
Local diagnostics (Ambient conditions)Supply voltage per module Green LED
Standards/regulations (Pin assignment)IEC 61076-2-101
Wire colors (Standards and Regulations)brown, blue, green/yellow, white, green, yellow, gray, gray/pink, red/blue, white/green, brown/green
Cable weight (Standards and Regulations)122 kg/km
UL AWM style (Standards and Regulations)20549
Ambient temperature (operation) (General)-30 °C ... 90 °C
Number of positions (Key Commercial Data)5
Overall twist (Standards and Regulations)Wires twisted in layers
Total rated current (Key Commercial Data)12 A
Bending radius (Standards and Regulations)87 mm
AWG signal line (Standards and Regulations)20
Traversing path (Standards and Regulations)2 m
Traversing rate (Standards and Regulations)2 m/s
AWG power supply (Standards and Regulations)17
Flame resistance (Standards and Regulations)DIN EN 50265
Length of cable (Local diagnostics function)5 m
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations)according to VDE 0472 Part 803
Cable abbreviation (Standards and Regulations)LiYY11Y-HF
Conductor material (Standards and Regulations)Bare Cu litz wires
Connection method (Local diagnostics function)Fixed connection
O-ring material (Master cable connection data)NBR
Special properties (Standards and Regulations)Silicone-free
Contact material (Master cable connection data)Cu alloy
Housing material (Master cable connection data)PBT
Test voltage, cable (Standards and Regulations)2000 V
Connection in acc. with standard (Pin assignment)CUL
Max. operating voltage Umax (Key Commercial Data)30 V DC
External sheath, color (Standards and Regulations)black RAL 9005
Inner sheath thickness (Standards and Regulations)≥ 0.15 mm
Material, inner sheath (Standards and Regulations)PVC
Nominal voltage, cable (Standards and Regulations)300 V
Outer sheath thickness (Standards and Regulations)≥ 0.38 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)8x 0.5 mm² (Signal line)
Number of bending cycles (Standards and Regulations)1500000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)8.7 mm ±0.2 mm
Contact carrier material (Master cable connection data)PA
Contact surface material (Master cable connection data)gold-plated
Sensor/actuator connection system (Key Commercial Data)M12-SPEEDCON-socket
Current carrying capacity per slot (Key Commercial Data)4 A
Material conductor insulation (Standards and Regulations)PVC
Material of threaded sleeve (Master cable connection data)Zinc die-cast
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 90 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)28x 0.15 mm
Material of the moulding mass (Master cable connection data)PUR
Core diameter including insulation (Standards and Regulations)1.5 mm ±0.1 mm (Signal line)
Current carrying capacity per I/O signal (Key Commercial Data)2 A
Slot/position = Wire color or connection (Insulation material)1 / 4 (A) = WH
Conductor structure, voltage supply (Standards and Regulations)56x 0.15 mm
Material of threaded sleeve surface (Master cable connection data)Nickel-plated
Minimum bending radius, fixed installation (Standards and Regulations)7.5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Tightening torque slot sensor/actuator cable (Local diagnostics function)0.4 Nm
Tightening torque of mounting screw for fixing the housing (Local diagnostics function)0.5 Nm

Product Description

Sensor/actuator box, application: Standard, connection type: SPEEDCON M12 Metal female connector, number of plug-in stations: 4, number of poles: 5, coding: A - standard, occupancy of plug-in stations
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty