| Parameter | Value |
|---|---|
| GTIN | 4017918899431 |
| Note | Made to Order (non-returnable) |
| (Cable) | No hazardous substances above threshold values |
| Orderkey | 1695799 |
| (General) | -5 °C ... 80 °C (for flexible installation) |
| Catalog page | Page 274 (C-2-2017) |
| Packing unit | 1 pc |
| Country of origin | PL (Poland) |
| China RoHS (Cable) | Environmentally friendly use period: unlimited = EFUP-e |
| Custom tariff number | 85444290 |
| (Insulation material) | 1-4 / 5 (PE) = GN/YE |
| (Key Commercial Data) | 60 V DC |
| (Standards and Regulations) | -5 °C ... 80 °C (cable, flexible installation) |
| Degree of protection (General) | IP65 |
| Rated voltage (Key Commercial Data) | 48 V |
| Length of cable (Ambient conditions) | 10 m |
| Weight per Piece (excluding packing) | 1,897.460 g |
| Number of slots (Key Commercial Data) | 4 |
| Shielding (Standards and Regulations) | Tinned copper braided shield |
| Standard designation (Pin assignment) | M12 connector |
| Cable type (Standards and Regulations) | PUR/PVC shielded, black |
| Connection method (Ambient conditions) | Fixed connection |
| Standards/regulations (Pin assignment) | IEC 61076-2-101 |
| Wire colors (Standards and Regulations) | brown, blue, green/yellow, white, green, yellow, gray, gray/pink, red/blue, white/green, brown/green |
| Ambient temperature (operation) (General) | -25 °C ... 70 °C |
| Number of positions (Key Commercial Data) | 5 |
| Overall twist (Standards and Regulations) | Wires twisted in layers |
| Total rated current (Key Commercial Data) | 12 A |
| Bending radius (Standards and Regulations) | 94 mm |
| AWG signal line (Standards and Regulations) | 20 |
| Traversing path (Standards and Regulations) | 2 m |
| Traversing rate (Standards and Regulations) | 2 m/s |
| AWG power supply (Standards and Regulations) | 17 |
| Flame resistance (Standards and Regulations) | DIN EN 50265 |
| Other resistance (Standards and Regulations) | Highly resistant to acids, alkaline solutions and solvents |
| Resistance to oil (Standards and Regulations) | according to VDE 0472 Part 803 |
| Cable abbreviation (Standards and Regulations) | LiYY11Y-HF |
| Conductor material (Standards and Regulations) | Bare Cu litz wires |
| O-ring material (Master cable connection data) | NBR |
| Special properties (Standards and Regulations) | Silicone-free |
| Contact material (Master cable connection data) | Cu alloy |
| Housing material (Master cable connection data) | Aluminum |
| Test voltage, cable (Standards and Regulations) | 2000 V |
| External sheath, color (Standards and Regulations) | deep black RAL 9005 |
| Nominal voltage, cable (Standards and Regulations) | 300 V |
| Outer sheath, material (Standards and Regulations) | PUR |
| Conductor cross section (Standards and Regulations) | 8x 0.5 mm² (Signal line) |
| Number of bending cycles (Standards and Regulations) | 1500000 |
| Cable type (abbreviation) (Standards and Regulations) | PUR |
| External cable diameter D (Standards and Regulations) | 9.4 mm ±0.2 mm |
| Contact carrier material (Master cable connection data) | PA |
| Contact surface material (Master cable connection data) | gold-plated |
| Flammability rating according to UL 94 (Pin assignment) | V0 |
| Housing surface material (Master cable connection data) | Nickel-plated |
| Sensor/actuator connection system (Key Commercial Data) | M12 socket |
| Current carrying capacity per slot (Key Commercial Data) | 4 A |
| Material conductor insulation (Standards and Regulations) | PVC |
| Material of threaded sleeve (Master cable connection data) | Aluminum |
| Ambient temperature (operation) (Standards and Regulations) | -40 °C ... 90 °C (cable, fixed installation) |
| Conductor structure signal line (Standards and Regulations) | 64x 0.10 mm |
| Flammability rating according to UL 94 (Key Commercial Data) | V0 |
| Material of the moulding mass (Master cable connection data) | PUR |
| Current carrying capacity per I/O signal (Key Commercial Data) | 2 A |
| Slot/position = Wire color or connection (Insulation material) | 1 / 4 (A) = WH |
| Conductor structure, voltage supply (Standards and Regulations) | 128x 0.10 mm |
| Tightening torque slot sensor/actuator cable (Ambient conditions) | 0.4 Nm |
| Material of contact, master cable side (Master cable connection data) | CU alloy |
| Material of contact surface, master cable side (Master cable connection data) | Gold-plated |
Technical specifications and performance data