Key Specifications
GTIN:4046356142977
Note:Made to Order (non-returnable)
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1548532
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356142977
NoteMade to Order (non-returnable)
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1548532
(General)-5 °C ... 80 °C (for flexible installation)
Catalog pagePage 272 (C-2-2017)
Packing unit1 pc
Country of originPL (Poland)
China RoHS (Cable)Environmentally Friendly Use Period = 50
Custom tariff number85444290
(Ambient conditions)Status display I/O Yellow LED
(Insulation material)1-4 / 3 (0 V) = BU
(Standards and Regulations)-5 °C ... 70 °C (cable, flexible installation)
Degree of protection (General)IP65
Contact material (Conductor data)Steel/copper
Housing material (Conductor data)PBT
Rated voltage (Key Commercial Data)24 V DC
Weight per Piece (excluding packing)778.500 g
Number of slots (Key Commercial Data)4
Cable type (Standards and Regulations)PUR/PVC black
Local diagnostics (Ambient conditions)Supply voltage Green LED
Cable weight (Standards and Regulations)112 kg/km
Ambient temperature (operation) (General)-30 °C ... 80 °C
Contact carrier material (Conductor data)PA 6.6
Contact surface material (Conductor data)Sn
Number of positions (Key Commercial Data)4
Overall twist (Standards and Regulations)Wires twisted in layers
Total rated current (Key Commercial Data)12 A
Bending radius (Standards and Regulations)87 mm
AWG signal line (Standards and Regulations)22
Traversing path (Standards and Regulations)2 m
Traversing rate (Standards and Regulations)2 m/s
AWG power supply (Standards and Regulations)18
Length of cable (Local diagnostics function)5 m
Cable abbreviation (Standards and Regulations)LiYY11Y-HF
Conductor material (Standards and Regulations)Bare Cu litz wires
Connection method (Local diagnostics function)Fixed connection
Material of the moulding mass (Conductor data)PUR
Connection in acc. with standard (Pin assignment)CUL
Max. operating voltage Umax (Key Commercial Data)30 V DC
External sheath, color (Standards and Regulations)deep black RAL 9005
Material, inner sheath (Standards and Regulations)PVC
Nominal voltage, cable (Standards and Regulations)≤ 500 V
Outer sheath, material (Standards and Regulations)PUR
Test voltage Core/Core (Standards and Regulations)1500 V AC (Signal line)
Conductor cross section (Standards and Regulations)8x 0.34 mm² (Signal line)
Number of bending cycles (Standards and Regulations)1500000
External cable diameter D (Standards and Regulations)8.7 mm ±0.2 mm
Wrench size, union nut (Master cable connection data)13 mm
Flammability rating according to UL 94 (Pin assignment)V0
Sensor/actuator connection system (Key Commercial Data)QUICKON
Wire insulation material (Master cable connection data)PVC / PE /PP
Current carrying capacity per slot (Key Commercial Data)4 A
Material conductor insulation (Standards and Regulations)PVC
Ambient temperature (operation) (Standards and Regulations)-30 °C ... 70 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Tightening torque, union nut (Master cable connection data)2 Nm
Flammability rating according to UL 94 (Key Commercial Data)V0
Core diameter including insulation (Standards and Regulations)1.5 mm (Signal line)
Current carrying capacity per I/O signal (Key Commercial Data)2 A
Slot/position = Wire color or connection (Insulation material)1 / 4 (A) = WH
Conductor cross section AWG max. (Master cable connection data)22
Conductor cross section AWG min. (Master cable connection data)26
Conductor structure, voltage supply (Standards and Regulations)96x 0.10 mm
Wire diameter including insulation (Master cable connection data)0.7 mm ... 1.3 mm
Maximum external conductor diameter (Master cable connection data)6 mm
Minimum external conductor diameter (Master cable connection data)3.5 mm
Conductor cross section flexible max. (Master cable connection data)0.34 mm²
Conductor cross section flexible min. (Master cable connection data)0.14 mm²
Smallest bending radius, fixed installation (Standards and Regulations)43.5 mm
Smallest bending radius, movable installation (Standards and Regulations)87 mm
Tightening torque of mounting screw for fixing the housing (Local diagnostics function)0.5 Nm
Structure of individual litz in acc. with VDE 0295 / smallest wire diameter (Master cable connection data)Class 2-6

Product Description

Sensor/Actuator Box, Application: Standard, Connection Type: QUICKON, 0.14 mm² ... 0.34 mm², number of plug-in stations: 4, number of poles: 4, occupancy of plug-in stations: Double, status indication
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty