Service time: Monday to Friday 9:00-18:00
SAC4P1,025-PURM8SIFS 0,34FCB+W - SAC4P1,025-PURM8SIFS 0,34FCB+W 1085293 PHOENIX CONTACT Sensor/actuator cable, 4-position, PUR halogen-free, ..
In Stock Hot Product

SAC4P1,025-PURM8SIFS 0,34FCB+W

SAC4P1,025-PURM8SIFS 0,34FCB+W 1085293 PHOENIX CONTACT Sensor/actuator cable, 4-position, PUR halogen-free, ..

$0.00USD
4549 in stock
Key Specifications
GTIN:4055626873343
(Cable):No hazardous substances above threshold values
Orderkey:1085293
(Drawings):
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626873343
(Cable)No hazardous substances above threshold values
Orderkey1085293
(Drawings)
Packing unit1
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
Custom tariff number85444290
(Ambient conditions)60 V DC
Contact material (General)CuSn
Length of cable (Drawings)1.025 m
Sealing material (General)NBR
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)brown, white, blue, black
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)30 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)4
UL AWM style (Standards and Regulations)20549 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations)4 wires, twisted
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)47 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
AWG signal line (Standards and Regulations)22
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)according to UL 758/1581 (horizontal)
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)Li9Y11Y-HF
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)≥ 3000 V
Conductor resistance (Standards and Regulations)≤ 58 Ω/km
Dimensional drawingM8 snap-in sockets (Drawings)
Flammability rating according to UL 94 (General)HB
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 1 GΩ*km
Thickness, insulation (Standards and Regulations)≥ 0.21 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V
Outer sheath thickness (Standards and Regulations)approx. 0.8 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)4x 0.34 mm²
Number of bending cycles (Standards and Regulations)4000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)4.7 mm ±0.15 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.27 mm ±0.02 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Smallest bending radius, fixed installation (Standards and Regulations)23.5 mm
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Smallest bending radius, movable installation (Standards and Regulations)47 mm
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D
Schematic diagramPin assignment M8 socket, 4-pos., view female side (Drawings)

Product Description

Sensor/actuator cable, 4-pole, halogen-free PUR, greyish black RAL 7021, free cable end, to M8 straight connection female, cable length: 1.025 m, Customer variant
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingM8 snap-in sockets

Product Documents