| Parameter | Value |
|---|---|
| EAN | Four trillion forty six billion three hundred fifty six million one hundred eighty one thousand three hundred seventy two |
| (Cable) | You will find information about hazardous substances in the manufacturer's declaration in the "Downloads"tab |
| Key order | One million five hundred fifty six thousand seven hundred two |
| (Measures) | IP67 |
| Key selling | BF1CMA - |
| Packing unit | 1 pcs |
| China RoHS (Cable) | Space of time for the intended use (FEUP): 50 years |
| REACh SVHC (Cable) | Lead 7439-92-1 |
| Tariff number tariff | Eighty five million four hundred forty four thousand two hundred ninety |
| (Environmental conditions) | 30 V DC |
| Material contact (Overview) | CuZn |
| Material knurled (Overview) | Die-cast zinc, nickel plated |
| Material body grip (Overview) | TPU fire-retardant, self-extinguishing |
| Cable length (Data commercial) | 3 m |
| Index of protection (Measures) | IP65 |
| (Standards and specifications) | -25 °C ... 80 °C (cable, available mobile) |
| Material of the board (Overview) | NBR |
| Unit weight (excluding packaging) | 189,900 g |
| Encoding (Environmental conditions) | A - standard |
| Material contact surface (Overview) | Ni/Au |
| Room temperature (service) (Measures) | -25 °C ... 90 °C (male / female) |
| Material support of contacts (Overview) | TPU GF |
| Shielding (Standards and specifications) | Mesh of copper wires tinned |
| Category surge (Environmental conditions) | II |
| Tension sizing (Environmental conditions) | 30 V AC |
| Number of poles (Environmental conditions) | Eight |
| Acceleration (Standards and specifications) | 10 m/s2 |
| Pollution degree (Environmental conditions) | Three |
| UL AWM Style (Standards and specifications) | 20549 / 10493 (80 °C/300 V) |
| Cabling total (Standards and specifications) | 8 drivers about filling it as the soul |
| Colors driver (Standards and specifications) | Brown, white, green, yellow, gray, pink, blue, red |
| Forward speed (Standards and specifications) | 3 m/s |
| Status indication (Environmental conditions) | Not |
| Type of cable (Standards and specifications) | PUR halogen-free black |
| Journey forward (Standards and specifications) | 10 m |
| Other resistors (Standards and specifications) | resistant to hydrolysis and microbes |
| Flame resistance (Standards and specifications) | according to UL FT-2 |
| Signal cable AWG (Standards and specifications) | Twenty four |
| Special features (Standards and specifications) | suitable for drag chain |
| Insulation resistance (Environmental conditions) | ≥ 100 MΩ |
| Outer wrap, color (Standards and specifications) | black-grey RAL 7021 |
| Section of driver (Standards and specifications) | 8x 0.25 mm2 (driver signals) |
| Absence of halogen (Standards and specifications) | according to DIN VDE 0472 part 815 |
| Test voltage Cable (Standards and specifications) | ≥ 3000 V AC Test (spark) |
| Conductive Material (Standards and specifications) | Conductor Cu bare |
| Cover visual screen (Standards and specifications) | 85 % |
| Rated voltage Cable (Standards and specifications) | ≤ 300 V AC |
| Weight of the cable (Standards and specifications) | 53 kg/km |
| Class of flammability according to UL 94 (Material) | HB |
| Class of flammability according to UL 94 (Overview) | HB |
| Current sizing at 40 °C (Environmental conditions) | 2 To |
| Abbreviation of cable (Standards and specifications) | LiF9YC11Y |
| Insulation resistance (Standards and specifications) | ≥ 1 GΩ*km (at 20 °C) |
| Outer casing, material (Standards and specifications) | PUR |
| Number of bending cycles (Standards and specifications) | Two million |
| Cable type (abbreviation) (Standards and specifications) | PUR |
| Outer diameter of cable D (Standards and specifications) | To 5.9 mm ±0.2 mm |
| Wall thickness outer wrap (Standards and specifications) | approx. 0.5 mm |
| Room temperature (service) (Standards and specifications) | -40 °C ... 80 °C (cable, fixed) |
| Resistance of the conductor (Standards and specifications) | ≤ 78 Ω/km (at 20 °C) |
| Thickness of wall Insulation (Standards and specifications) | approx. 0.2 mm |
| Material Insulation conductor (Standards and specifications) | PP |
| Test voltage Conductor/Screen (Standards and specifications) | ≥ 2000 V AC (For 60 s) |
| Construction of the driver signal cable (Standards and specifications) | 32x 0.10 mm |
| Radius of curvature, insert drag chains (Standards and specifications) | 10 x D |
| Diameter of the conductors, insulation included (Standards and specifications) | 1,17 mm ±0.02 mm |
| Minimum bending radius, placed in a fixed manner (Standards and specifications) | 5 x D |
| Minimum bending radius, placed in a flexible way (Standards and specifications) | 10 x D |