Service time: Monday to Friday 9:00-18:00
SAC-8P-M12MS/50-28X/M12FSSHOD - SAC-8P-M12MS/50-28X/M12FSSHOD 1420783 PHOENIX CONTACT Sensor/actuator cable SAC-8P-M12MS/50-28X/M12FSSHOD 14..
In Stock Hot Product

SAC-8P-M12MS/50-28X/M12FSSHOD

SAC-8P-M12MS/50-28X/M12FSSHOD 1420783 PHOENIX CONTACT Sensor/actuator cable SAC-8P-M12MS/50-28X/M12FSSHOD 14..

$0.00USD
3555 in stock
Key Specifications
GTIN:4055626239798
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1420783
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626239798
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1420783
Packing unit1
(Dimensions)
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
Custom tariff number85444290
(Ambient conditions)30 V DC
Contact material (General)CuSn
Material, knurls (General)Stainless steel
Sealing material (General)FPM
Coding (Ambient conditions)A - standard
(Standards and Regulations)20 °C ±5 °C (cable, drag chain applications)
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)PP
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Contact carrier material (General)PP
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)30 V AC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)50 m
Shielding (Standards and Regulations)Braided copper wires
Cable type (Standards and Regulations)PE-X black
Wire colors (Standards and Regulations)white, brown, green, yellow, gray, pink, blue, red
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)81 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)8
Overall twist (Standards and Regulations)8 wires around filler to the core
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)24
Rated current at 40°C (Ambient conditions)2 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-40 °C ... 105 °C (Plug / socket)
Flame resistance (Standards and Regulations)According to DIN EN 60332-1-2
Material, filler (Standards and Regulations)PP yarn
Other resistance (Standards and Regulations)Resistance to fuels according to IEC 60811, 168 h at 70°C
Resistance to oil (Standards and Regulations)According to DIN EN 60811-2-1, 168 h at 100°C
Cable abbreviation (Standards and Regulations)Li2X2X-C-V1-2X
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Inductance approx. 0.48 mH/km
Test voltage, cable (Standards and Regulations)≥ 3000 V AC (Spark test)
Working capacitance (Standards and Regulations)approx. 80 pF (core-core)
Conductor resistance (Standards and Regulations)≤ 78 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)V0
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 100 MΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)approx. 0.25 mm (Core insulation)
External sheath, color (Standards and Regulations)black-gray RAL 7021
Inner sheath thickness (Standards and Regulations)approx. 0.5 mm
Material, inner sheath (Standards and Regulations)PE-X
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath thickness (Standards and Regulations)approx. 0.7 mm
Outer sheath, material (Standards and Regulations)PE-X
Conductor cross section (Standards and Regulations)8x 0.25 mm²
Optical shield covering (Standards and Regulations)85 %
Number of bending cycles (Standards and Regulations)1000000
Test voltage Core/Shield (Standards and Regulations)≥ 1000 V AC (for 10 s)
Cable type (abbreviation) (Standards and Regulations)28X
External cable diameter D (Standards and Regulations)7.25 mm ±0,3 mm
Material conductor insulation (Standards and Regulations)PE-X
Length of twist, overall twist (Standards and Regulations)67 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 105 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)32x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.17 mm ±0.02 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 8-position, PE-X/PE-X halogen-free, black-gray RAL 7021, shielded, cable length: 50 m, for outdoor applications, with high-grade steel knurl

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top