Service time: Monday to Friday 9:00-18:00
SAC-8P-M12MS/5,0-513/M12FS SH8 - SAC-8P-M12MS/5,0-513/M12FS SH8 1409744 PHOENIX CONTACT Sensor/actuator cable SAC-8P-M12MS/5,0-513/M12FS SH8 ..
In Stock Hot Product

SAC-8P-M12MS/5,0-513/M12FS SH8

SAC-8P-M12MS/5,0-513/M12FS SH8 1409744 PHOENIX CONTACT Sensor/actuator cable SAC-8P-M12MS/5,0-513/M12FS SH8 ..

$0.00USD
4867 in stock
Key Specifications
GTIN:4046356881012
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1409744
(Material):Resistant to salt water
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356881012
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1409744
(Material)Resistant to salt water
Packing unit1
(Dimensions)IP67
UNSPSC 11 (ETIM)31251501
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
UNSPSC 13.2 (ETIM)31251501
UNSPSC 6.01 (ETIM)31251501
UNSPSC 12.01 (ETIM)31251501
Custom tariff number85444290
UNSPSC 7.0901 (ETIM)31251501
(Ambient conditions)30 V DC
Halogen-free (Material)in accordance with DIN VDE 0472 part 815
Contact material (General)CuZn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
Flame resistance (Material)in accordance with DIN UL-Style 20549
Other resistance (Material)hydrolysis and microbe resistant
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
Resistance to oil (Material)in accordance with DIN EN 60811-2-1
eCl@ss 4.0 (Classifications)27060306
eCl@ss 4.1 (Classifications)27060306
eCl@ss 5.0 (Classifications)27061801
eCl@ss 5.1 (Classifications)27061800
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Standard designation (Material)M12 connector
Degree of protection (Dimensions)IP65
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)30 V AC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)5 m
Shielding (Standards and Regulations)Plastic-coated aluminum foil with a drain wire
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)white, brown, green, yellow, gray, pink, blue
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)49 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)8
UL AWM style (Standards and Regulations)20549 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations)Seven wires around the filler to the core
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)50 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector
AWG signal line (Standards and Regulations)24
Rated current at 40°C (Ambient conditions)2 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Flame resistance (Standards and Regulations)in accordance with DIN UL-Style 20549
Material, filler (Standards and Regulations)PE
Other resistance (Standards and Regulations)hydrolysis and microbe resistant
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)Li9Y-St-11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Shielding material (Standards and Regulations)Al19PES23
Special properties (Standards and Regulations)not suited to drag chain applications
Test voltage, cable (Standards and Regulations)≥ 3000 V
Conductor resistance (Standards and Regulations)≤ 78 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 100 GΩ*km (at 20 °C)
Thickness, insulation (Standards and Regulations)≥ 0.21 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V
Outer sheath thickness (Standards and Regulations)≥ 0.38 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)7x 0.25 mm² (Signal line)
Number of bending cycles (Standards and Regulations)30000
Cable type (abbreviation) (Standards and Regulations)513
External cable diameter D (Standards and Regulations)6 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)32x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.17 mm ±0.02 mm (Signal line)
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D

Product Description

Sensor/actuator cable, 8-pole, halogen-free PUR, grayish black RAL 7021, shielded, M12 straight male connector, encoding: A-encoded, to M12 straight-connecting female, encoding: A-encoded, cable lengt
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 8-position, PUR halogen-free, black-gray RAL 7021, shielded, Plug straight M12, A-coded, on Socket straight M12, A-coded, cable length: 5 m, Customer version

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top