| Parameter | Value |
|---|---|
| 30 V DC | |
| Type | Plug straight M12 |
| Coding | A |
| Shielded | yes |
| Cable type | PUR halogen-free black [513] |
| Coding type | A |
| Cable length | 20 m |
| Cable weight | 49 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Product type | Sensor/actuator cable |
| Test voltage | ≥ 3000 V |
| UL AWM Style | 20549 / 10493 (80°C/300 V) |
| Overall twist | Seven wires around the filler to the core |
| Seal material | NBR |
| Conductor type | Round cable |
| Status display | no |
| AWG signal line | 24 |
| Contact material | CuZn |
| Flame resistance | in accordance with DIN UL-Style 20549 |
| Material, filler | PE |
| Other resistance | hydrolysis and microbe resistant |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Conductor material | Bare Cu litz wires |
| Nominal current IN | 2 A |
| Nominal voltage UN | 30 V AC |
| Shielding material | Al19PES23 |
| Single wire, color | white, brown, green, yellow, gray, pink, blue |
| Special properties | not suited to drag chain applications |
| Degree of pollution | 3 |
| Number of positions | 8 |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Standard designation | M12 connector |
| Insulation resistance | ≥ 100 MΩ |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Thickness, insulation | ≥ 0.21 mm |
| External sheath, color | black-gray RAL 7021 |
| Nominal voltage, cable | ≤ 300 V |
| Outer sheath, material | PUR |
| Status display present | No |
| Conductor cross section | 7x 0.25 mm² (Signal line) |
| External cable diameter | 6.00 mm ±0.2 mm |
| Thickness, outer sheath | ≥ 0.38 mm |
| Contact carrier material | TPU GF |
| Contact surface material | Ni/Au |
| Material wire insulation | PP |
| Max. conductor resistance | ≤ 78 Ω/km (at 20 °C) |
| Insertion/withdrawal cycles | ≥ 100 |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Wire diameter incl. insulation | 1.17 mm ±0.02 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 32x 0.10 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 30000, Bending radius: 50 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s² |
| Flammability rating according to UL 94 | HB |
| Minimum bending radius, fixed installation | 5 x D |
| Smallest bending radius, fixed installation | 30 mm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 60 mm |
Technical specifications and performance data