Service time: Monday to Friday 9:00-18:00
SAC-8P-M12MS/0,2-PUR/FS SH 2X8 - SAC-8P-M12MS/0,2-PUR/FS SH 2X8 1103877 PHOENIX CONTACT Sensor/actuator cable, 8-position, PUR halogen-free, ..
In Stock Hot Product

SAC-8P-M12MS/0,2-PUR/FS SH 2X8

SAC-8P-M12MS/0,2-PUR/FS SH 2X8 1103877 PHOENIX CONTACT Sensor/actuator cable, 8-position, PUR halogen-free, ..

$0.00USD
3192 in stock
Key Specifications
GTIN:4055626968988
Orderkey:1103877
(Drawings):
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626968988
Orderkey1103877
(Drawings)
Packing unit1
(Dimensions)30 V DC
Coding (Dimensions)A - standard
Custom tariff number85444290
Contact material (General)CuZn
Length of cable (Drawings)0.2 m
Material, knurls (General)Zinc die-cast, nickel-plated
Rated voltage (Dimensions)30 V AC
Sealing material (General)NBR
Status display (Dimensions)No
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Degree of pollution (Dimensions)3
Number of positions (Dimensions)8
Overvoltage category (Dimensions)II
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Insulation resistance (Dimensions)≥ 100 MΩ
Standards/regulations (Dimensions)M12 connector IEC 61076-2-101
Rated current at 40°C (Dimensions)2 A
Standards/specifications (Material)M12 connector IEC 61076-2-101
Shielding (Standards and Regulations)Tinned copper braided shield
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)Brown, white, green, yellow, gray, pink, blue, red
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)53 kg/km
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
UL AWM style (Standards and Regulations)20549 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations)8 wires around filler to the core
Protective circuit/component (Dimensions)unwired
AWG signal line (Standards and Regulations)24
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Flame resistance (Standards and Regulations)in acc. with UL FT-2
Other resistance (Standards and Regulations)hydrolysis and microbe resistant
Cable abbreviation (Standards and Regulations)LiF9YC11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)≥ 3000 V AC (Spark test)
Conductor resistance (Standards and Regulations)≤ 78 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 1 GΩ*km (at 20 °C)
Thickness, insulation (Standards and Regulations)approx. 0.2 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath thickness (Standards and Regulations)approx. 0.5 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)8x 0.25 mm² (Signal line)
Optical shield covering (Standards and Regulations)85 %
Number of bending cycles (Standards and Regulations)2000000
Test voltage Core/Shield (Standards and Regulations)≥ 2000 V AC (for 60 s)
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)5.9 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)32x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.17 mm ±0.02 mm
Dimensional drawingPlug, M12 x 1, straight, shielded (Drawings)
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D
Circuit diagramContact assignment of the M12 plug and the M12 socket (Drawings)
Schematic diagramPin assignment M12 socket, 8-pos., A-coded, view female side (Drawings)

Product Description

Sensor/actuator cable, 8-pole, halogen-free PUR, greyish black RAL 7021, shielded, cable length: 0.2 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingPlug, M12 x 1, straight, shielded

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top