| Parameter | Value |
|---|---|
| GTIN | Four trillion forty six billion three hundred fifty six million five hundred eighty two thousand four hundred seven |
| Note | The production is linked to the application (no removal) |
| (Measures) | IP67 |
| (The line) | For more information on hazardous materials, see manufacturer's declaration in the Download |
| UNSPSC 11 (ETIM) | Thirty one million two hundred fifty one thousand five hundred one |
| ETIM 3.0 (eCl@ss) | EC001855 |
| ETIM 4.0 (eCl@ss) | EC001855 |
| ETIM 5.0 (eCl@ss) | EC001855 |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| UNSPSC 13.2 (ETIM) | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 6.01 (ETIM) | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 12.01 (ETIM) | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 7.0901 (ETIM) | Thirty one million two hundred fifty one thousand five hundred one |
| eCl@ss 5.1 (Ratings) | Twenty seven million sixty one thousand eight hundred |
| eCl@ss 6.0 (Ratings) | Twenty seven million two hundred seventy nine thousand two hundred |
| eCl@ss 7.0 (Ratings) | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 8.0 (Ratings) | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| REACh-SVHC (The line) | |
| The country-of-origin | PL (Poland). |
| As China RoHS (The line) | The period for the approved purpose (EFUP) is 50 years old |
| the eCl@ss 4.0 (Ratings) | Twenty seven million sixty thousand three hundred six |
| the eCl@ss 4.1 (Ratings) | Twenty seven million sixty thousand three hundred six |
| the eCl@ss 5.0 (Ratings) | Twenty seven million sixty one thousand eight hundred one |
| the eCl@ss 9.0 (Ratings) | Twenty seven million sixty thousand three hundred eleven |
| (Environmental conditions) | 30 V DC |
| The code of the application | One million four hundred forty five thousand two hundred twenty four |
| The amount of the package (C#) | 1 Unit |
| Coding (Environmental conditions) | The standard |
| The minimum quantity of the order | 15 Pcs |
| (The rules and the provisions of) | -25 °C ... 80 °C (Cable, available to a mobile) |
| The length of the cable (Business) | A 5-m |
| The degree of protection (Measures) | IP65 |
| Weight per piece (excluding packing) | 292,700 GRM |
| The number of corporate and commercial | Eighty five million four hundred forty four thousand two hundred ninety |
| Rated voltage (Environmental conditions) | 30 V AC |
| The Material of the anti - (The general) | Zinc die casting is under pressure, nickel-plated |
| The Material of the contact (The general) | CuZn |
| The Material of the sealing (The general) | O |
| The shield (The rules and the provisions of) | wire, copper-plated or coated with zinc |
| Over voltage category (Environmental conditions) | II |
| The Material supporting the contact (The general) | TPU GF |
| Rated current at 40 °C (Environmental conditions) | Two |
| Special features (The rules and the provisions of) | himself to the door-handles |
| The acceleration (The rules and the provisions of) | 10 m/s2) |
| The degree of impurity, (Environmental conditions) | Three |
| Cable type (code) (The rules and the provisions of) | PURE |
| Stranded in total (The rules and the provisions of) | The 8 conductors in the core of soul |
| The Material of the body of the cable (The general) | TPU, hardly inflammable, self-extinguishing |
| The type of cable (The rules and the provisions of) | PUR halogen-free black |
| Material on the surface of the contact (The general) | Ni/Au |
| Outer shell, color (The rules and the provisions of) | the black-gray RAL 7021 |
| The number of poles in the (Environmental conditions) | Eight |
| The other resistors (The rules and the provisions of) | resistant to hydrolysis and microbes. |
| Class of flammability according to UL 94 (The general) | Hemoglobin (HB) |
| Class of flammability according to UL 94 (The Material) | Hemoglobin (HB) |
| The Anti-flammability (The rules and the provisions of) | according to to UL FT-2 in |
| An indication of the state of (Environmental conditions) | Don't |
| The code for the cable (The rules and the provisions of) | LiF9YC11Y |
| The color of the driver (The rules and the provisions of) | brown, blue, green, yellow, white, pink, blue, and red |
| The course of the shift (The rules and the provisions of) | A 10-m |
| The speed of the scroll (The rules and the provisions of) | 3 m/sec. |
| The style of the UL AWM (The rules and the provisions of) | 20549 / 10493 (80 °C / 300 V) |
| The value of the driver (The rules and the provisions of) | 8x 0.25 mm2 (signal Line) |
| The weight of the cable (The rules and the provisions of) | 53 kg/km |
| The resistance of the insulation (Environmental conditions) | ≥ 100 MΩ |
| The line of the signal WIRE (The rules and the provisions of) | Twenty four |
| Test voltage conductor/screen (The rules and the provisions of) | At ≥ 2000 V AC (for 60 s), |
| The Material of the conductor (The rules and the provisions of) | Copper cable |
| The absence of a halogen-free (The rules and the provisions of) | acc. to DIN VDE 0472 part 815 |
| An external covering material, (The rules and the provisions of) | PURE |
| The voltage of the test of the (The rules and the provisions of) | ≥ 3000 V AC (Test for spark) |
| Ambient temperature (operation) (The rules and the provisions of) | Operating temperature: -40 °C ... 80 °C (Cable, available to set) |
| Number of cycles of the bending (The rules and the provisions of) | Two million |
| The nominal voltage of the line (The rules and the provisions of) | ≤ 300 V AC |
| The resistance of the conductor (The rules and the provisions of) | ≤ 78 Ω/km (at 20 °C) |
| The resistance of the insulation (The rules and the provisions of) | A ≥ 1 GΩ*km (at 20 °C) |
| The outer diameter of the cable D (The rules and the provisions of) | At 5.9 mm ±0.2 mm |
| The density of the wall insulation (The rules and the provisions of) | ca. 0.2 mm |
| Coverage of the visual of the shield (The rules and the provisions of) | 85 % |
| An insulating Material of the conductor (The rules and the provisions of) | PP |
| The thickness of the wall of outer Jacket (The rules and the provisions of) | ca. 0.5 mm |
| Minimum bend radius of, the position of the fixed (The rules and the provisions of) | 5 x D |
| The mounting of the conductive signal line on the (The rules and the provisions of) | 32x 0.10 mm |
| Minimum bend radius of, the position of the flexible (The rules and the provisions of) | 10 x D |
| The diameter of the conductor, including the insulation (The rules and the provisions of) | 1,17 mm ±0.02 mm |
| Minimum bend radius of insertion for the belt to drag-and-drop (The rules and the provisions of) | 10 x D |
Technical specifications and performance data