| Parameter | Value |
|---|---|
| 30 V DC | |
| Type | Plug angled M8 |
| Coding | A |
| Shielded | no |
| Cable type | PUR halogen-free black [PUR] |
| Application | Standard |
| Coding type | A |
| Cable length | 3 m |
| Cable weight | 31.4 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Product type | Sensor/actuator cable |
| Test voltage | ≥ 3000 V AC (Spark test) |
| UL AWM Style | 20549 |
| Overall twist | 8 wires around filler to the core |
| Status display | no |
| AWG signal line | 26 |
| Article revision | 04 |
| Contact material | CuSn |
| Flame resistance | according to UL 758/1581 (horizontal) |
| Material, filler | PE |
| Other resistance | hydrolysis and microbe resistant |
| Resistance to oil | According to DIN EN 60811-2-1, 168 h at 100°C |
| Tightening torque | 0.2 Nm (M8 connectors) |
| Conductor material | Bare Cu litz wires |
| Nominal current IN | 1.5 A |
| Nominal voltage UN | 30 V AC |
| Single wire, color | white, brown, green, yellow, gray, pink, blue, red |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 8 |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Standard designation | M8 connector |
| Insulation resistance | ≥ 100 MΩ |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Thickness, insulation | ≥ 0.21 mm (Signal line) |
| External sheath, color | black-gray RAL 7021 |
| Nominal voltage, cable | ≤ 300 V AC |
| Outer sheath, material | PUR |
| Status display present | No |
| Conductor cross section | 8x 0.14 mm² (Signal line) |
| External cable diameter | 5.10 mm ±0.15 mm |
| Contact carrier material | TPU GF |
| Contact surface material | Ni/Au |
| Material wire insulation | PP |
| Standards/specifications | IEC 61076-2-104 |
| Max. conductor resistance | 139 Ω/km (at 20 °C) |
| Insertion/withdrawal cycles | ≥ 100 |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Length of twist, overall twist | 58 mm |
| Wire diameter incl. insulation | 1 mm ±0.02 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 18x 0.10 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 4000000, Bending radius: 51 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s² |
| Flammability rating according to UL 94 | HB |
| Minimum bending radius, fixed installation | 5 x D |
| Smallest bending radius, fixed installation | 25.5 mm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 51 mm |