Service time: Monday to Friday 9:00-18:00
SAC-8P-50,0-PUR/M 8FS SH - SAC-8P-50,0-PUR/M 8FS SH 1422292 PHOENIX CONTACT Sensor/actuator cable SAC-8P-50,0-PUR/M 8FS SH 1422292
In Stock Hot Product

SAC-8P-50,0-PUR/M 8FS SH

SAC-8P-50,0-PUR/M 8FS SH 1422292 PHOENIX CONTACT Sensor/actuator cable SAC-8P-50,0-PUR/M 8FS SH 1422292

$0.00USD
3346 in stock
Key Specifications
GTIN:4055626297156
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1422292
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626297156
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1422292
Packing unit1
(Dimensions)30 V DC
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
UNSPSC 13.2 (ETIM)31251501
Coding (Dimensions)A - standard
Custom tariff number85444290
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Rated voltage (Dimensions)30 V AC
Sealing material (General)NBR
Status display (Dimensions)No
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 5.1 (Classifications)27061801
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Standard designation (Material)M8 connector
Degree of pollution (Dimensions)3
Number of positions (Dimensions)8
Standards/regulations (Material)IEC 61076-2-104
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Standards/regulations (Dimensions)M8 connector IEC 61076-2-104
Rated current at 40°C (Dimensions)1.5 A
Length of cable (Key Commercial Data)50 m
Shielding (Standards and Regulations)Tinned copper braided shield
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)white, brown, green, yellow, gray, pink, blue, red
Acceleration (Standards and Regulations)10 m/s²
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
UL AWM style (Standards and Regulations)20549
Overall twist (Standards and Regulations)8 wires around filler to the core
Protective circuit/component (Dimensions)unwired
Bending radius (Standards and Regulations)59 mm
AWG signal line (Standards and Regulations)26
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Flame resistance (Standards and Regulations)according to UL 758/1581 (horizontal)
Material, filler (Standards and Regulations)PE
Other resistance (Standards and Regulations)hydrolysis and microbe resistant
Resistance to oil (Standards and Regulations)According to DIN EN 60811-2-1, 168 h at 100°C
Cable abbreviation (Standards and Regulations)Li9YV1-C-V1-11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Test voltage, cable (Standards and Regulations)≥ 3000 V AC (Spark test)
Conductor resistance (Standards and Regulations)139 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)1 GΩ*km (at 20 °C)
Thickness, insulation (Standards and Regulations)≥ 0.21 mm (Signal line)
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)8x 0.14 mm² (Signal line)
Optical shield covering (Standards and Regulations)85 %
Number of bending cycles (Standards and Regulations)2000000
Test voltage Core/Shield (Standards and Regulations)≥ 2000 V AC (for 60 s)
External cable diameter D (Standards and Regulations)5.9 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PP
Length of twist, overall twist (Standards and Regulations)58 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)18x 0.10 mm
Core diameter including insulation (Standards and Regulations)1 mm ±0.02 mm (Signal line)
Smallest bending radius, fixed installation (Standards and Regulations)29.5 mm
Smallest bending radius, movable installation (Standards and Regulations)59 mm

Product Description

Sensor/actuator cable, 8-pole, halogen-free PUR, greyish black RAL 7021, screened, free cable end, to straight female M8, coding: A, cable length: 50 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 8-position, PUR halogen-free, black-gray RAL 7021, shielded, cable length: 50 m

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top