Technical Specifications

ParameterValue
GTIN4046356964906
Orderkey1412523
(Drawings)
Packing unit1
(Dimensions)IP68
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
REACh SVHC (Cable)Lead 7439-92-1
UNSPSC 13.2 (ETIM)31251501
UNSPSC 19.0 (ETIM)31251501
UNSPSC 20.0 (ETIM)31251501
UNSPSC 21.0 (ETIM)31251501
Custom tariff number85444290
(Ambient conditions)30 V DC
Contact material (General)CuSn
Length of cable (Drawings)5 m
Material, knurls (General)Zinc die-cast, nickel-plated
Coding (Ambient conditions)A - standard
Torque (Ambient conditions)0.2 Nm (M8 connectors)
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 5.1 (Classifications)27061800
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Degree of protection (Dimensions)IP65
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)30 V AC
Standards/specifications (Material)M8 connector IEC 61076-2-104
Status display (Ambient conditions)No
Wire colors (Standards and Regulations)white, brown, green, yellow, gray, pink, blue, red
Acceleration (Standards and Regulations)10 m/s²
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)8
UL AWM style (Standards and Regulations)20549
Overall twist (Standards and Regulations)8 wires around filler to the core
Bending radius (Standards and Regulations)51 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M8 connector IEC 61076-2-104
AWG signal line (Standards and Regulations)26
Rated current at 40°C (Ambient conditions)1.5 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 85 °C (Plug / socket)
Flame resistance (Standards and Regulations)according to UL 758/1581 (horizontal)
Material, filler (Standards and Regulations)PE
Other resistance (Standards and Regulations)hydrolysis and microbe resistant
Resistance to oil (Standards and Regulations)According to DIN EN 60811-2-1, 168 h at 100°C
Cable abbreviation (Standards and Regulations)Li9Y11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Test voltage, cable (Standards and Regulations)≥ 3000 V AC (Spark test)
Conductor resistance (Standards and Regulations)139 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)1 GΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)≥ 0.21 mm (Signal line)
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)8x 0.14 mm² (Signal line)
Dimensional drawingSocket M8 x 1, angled (Drawings)
Number of bending cycles (Standards and Regulations)4000000
External cable diameter D (Standards and Regulations)5.1 mm ±0.15 mm
Material conductor insulation (Standards and Regulations)PP
Length of twist, overall twist (Standards and Regulations)58 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)18x 0.10 mm
Core diameter including insulation (Standards and Regulations)1 mm ±0.02 mm (Signal line)
Smallest bending radius, fixed installation (Standards and Regulations)25.5 mm
Smallest bending radius, movable installation (Standards and Regulations)51 mm
Schematic diagramConnector pin assignment of M8 socket, 8-pos., view of socket side (Drawings)

Product Description

Sensor/actuator cable, 8-pole, halogen-free PUR, greyish black RAL 7021, free cable end, to Angled connection female M8, cable length: 5 m, Output direction C6
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingSocket M8 x 1, angled

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top