| Parameter | Value |
|---|---|
| GTIN | Four trillion fifty five billion six hundred twenty six million four hundred forty six thousand four hundred seventy nine |
| (Cable) | The manufacturer's declaration in the tab "Downloads" contains detailed information on hazardous substances. |
| (Ratings) | 30 V DC |
| Order Code | One million four hundred twenty six thousand one hundred twenty six |
| Packaging unit | One |
| ETIM 5.0 (eCl@ss) | EC001855 |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| China RoHS (Cable) | Period of intended use (EFUP) : 50 years |
| REACh SVHC (Cable) | |
| Tamperproof (Ratings) | A - standard |
| Seal material (General) | NBR |
| Status display (Ratings) | Not |
| Cable length (Trade data) | 0.9 m |
| Number of poles (Ratings) | Eight |
| Contact material (General) | CuZn |
| Pollution degree (Ratings) | Three |
| Reference voltage (Ratings) | 30 V AC |
| Number of the customs tariff | Eighty five million four hundred forty four thousand two hundred ninety |
| eCl@ss 6.0 (Classifications) | Twenty seven million two hundred seventy nine thousand two hundred |
| eCl@ss 7.0 (Classifications) | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 9.0 (Classifications) | Twenty seven million sixty thousand three hundred eleven |
| Overvoltage category (Ratings) | II |
| (Standards and specifications) | -25 °C ... 80 °C (cable, installation flexible) |
| Material of the wheel (General) | Zinc die-cast, nickel-plated |
| Standards/Requirements (Material) | IEC 61076-2-101 |
| Material of grip surface (General) | TPU, flame-retardant, self-extinguishing |
| Material of door-contacts (General) | TPU GF |
| Race (Standards and specifications) | 10 m |
| Standards / Specifications (Ratings) | M12 connector IEC 61076-2-101 |
| Material of contact surface (General) | Ni/Au |
| Reference current at 40 ℃ (Ratings) | Two |
| Circuit/component protection (Ratings) | disconnected |
| Designation of the standard (Material) | M12 Connector |
| Shielding (Standards and specifications) | Braid wire tinned copper |
| Acceleration (Standards and specifications) | 10 m/s2 |
| Style UL AWM (Standards and specifications) | 20549 / 10493 (80 °C / 300 V) |
| Symbol cable (Standards and specifications) | LiF9YC11Y |
| Cabling total (Standards and specifications) | 8 wires with 2 masses of padding in the direction of the soul |
| Type of cable (Standards and specifications) | PURE free halogen black |
| Movement speed (Standards and specifications) | 3 m/s |
| AWG line signals (Standards and specifications) | Twenty four |
| Flammability class according to UL 94 (General) | HB |
| Flammability class according to UL 94 (Material) | HB |
| Absence of halogen (Standards and specifications) | according to DIN VDE 0472 part 815 |
| Resistance special (Standards and specifications) | resistant to hydrolysis and microbes |
| Special properties (Standards and specifications) | compatible chain-cables |
| Test voltage cable (Standards and specifications) | ≥ 3000 V AC (spark Test) |
| Cable Type (symbol) (Standards and specifications) | PURE |
| Conductive material (Standards and specifications) | Cord Cu nu |
| Thickness isolation (Standards and specifications) | approximately 0.2 mm |
| Weight of the cable (Standards and specifications) | 53 kg/km |
| Colours of the wires (Standards and specifications) | brown, white, green, yellow, gray, pink, blue, red |
| Outer sheath, colour (Standards and specifications) | black-grey RAL 7021 |
| Insulation resistance (Standards and specifications) | ≥ 1 GΩ*km (at 20 °C) |
| Nominal voltage cable (Standards and specifications) | ≤ 300 V AC |
| Outer sheath, material (Standards and specifications) | PURE |
| Thickness outer sheath (Standards and specifications) | approx 0.5 mm |
| Number of bending cycles (Standards and specifications) | Two million |
| Test voltage wire/shield (Standards and specifications) | ≥ 2000 V AC (For 60 s) |
| Optical coating shielding (Standards and specifications) | 85 % |
| Resistance of the conductor (Standards and specifications) | ≤ 78 Ω/km (at 20 °C) |
| Cross Section of the conductor (Standards and specifications) | 8x 0.25 mm2 (signal Line) |
| Ambient temperature (operation) (Standards and specifications) | -40 °C ... 80 °C (cable, fixed installation) |
| Insulating material of the wire (Standards and specifications) | PP |
| Outside diameter of the cable D (Standards and specifications) | 5.9 mm ±0.2 mm |
| Diameter of wire with insulation (Standards and specifications) | 1.17 mm ±0.02 mm |
| Resistance to the spread of flames (Standards and specifications) | accordance with UL FT-2 |
| Lengths of the decladding of the end is not completed (Trade data) | 100 mm |
| Structure of the driver signal line (Standards and specifications) | 32x 0.10 mm |
| Minimum radius of curvature, fixed position (Standards and specifications) | 5 x D |
| Minimum radius of curvature, position flexible (Standards and specifications) | 10 x D |
| Minimum radius of curvature, use of chain-cables (Standards and specifications) | 10 x D |
Technical specifications and performance data
Installation and operation guide