| Parameter | Value |
|---|---|
| GTIN | 4055626449128 |
| (Cable) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Orderkey | 1426180 |
| Packing unit | 1 |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| China RoHS (Cable) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Cable) | |
| Custom tariff number | 85444290 |
| (Ambient conditions) | 30 V DC |
| Coding (Ambient conditions) | A - standard |
| (Standards and Regulations) | -5 °C ... 80 °C (cable, flexible installation) |
| eCl@ss 6.0 (Classifications) | 27279200 |
| eCl@ss 7.0 (Classifications) | 27279218 |
| eCl@ss 9.0 (Classifications) | 27060311 |
| Standard designation (Material) | M8 connector |
| Standards/regulations (Material) | IEC 61076-2-104 |
| Rated voltage (Ambient conditions) | 30 V AC |
| Status display (Ambient conditions) | No |
| Length of cable (Key Commercial Data) | 7 m |
| Cable type (Standards and Regulations) | PUR halogen-free black |
| Wire colors (Standards and Regulations) | Brown, white, black, blue, gray, pink |
| Acceleration (Standards and Regulations) | 10 m/s² |
| Cable weight (Standards and Regulations) | 34 kg/km |
| Degree of pollution (Ambient conditions) | 3 |
| Halogen-free (Standards and Regulations) | in accordance with DIN VDE 0472 part 815 |
| Number of positions (Ambient conditions) | 6 |
| Overvoltage category (Ambient conditions) | II |
| Bending radius (Standards and Regulations) | 52 mm |
| Standards/regulations (Ambient conditions) | M8 connector IEC 61076-2-104 |
| AWG signal line (Standards and Regulations) | 26 |
| Rated current at 40°C (Ambient conditions) | 1.5 A |
| Traversing path (Standards and Regulations) | 10 m |
| Traversing rate (Standards and Regulations) | 3 m/s |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 90 °C (Plug / socket) |
| Flame resistance (Standards and Regulations) | in accordance with DIN UL-Style 20549 |
| Other resistance (Standards and Regulations) | Highly resistant to acids, alkaline solutions and solvents |
| Resistance to oil (Standards and Regulations) | in accordance with DIN EN 60811-2-1 |
| Conductor material (Standards and Regulations) | Bare Cu litz wires |
| Special properties (Standards and Regulations) | Flexible cable conduit capable |
| Flammability rating according to UL 94 (General) | HB |
| Flammability rating according to UL 94 (Material) | HB |
| Protective circuit/component (Ambient conditions) | unwired |
| External sheath, color (Standards and Regulations) | black-gray RAL 7021 |
| Outer sheath, material (Standards and Regulations) | PUR |
| Conductor cross section (Standards and Regulations) | 6x 0.14 mm² (Signal line) |
| External cable diameter (Standards and Regulations) | 5.20 mm |
| Number of bending cycles (Standards and Regulations) | 4000000 |
| Cable type (abbreviation) (Standards and Regulations) | PUR |
| Ambient temperature (operation) (Standards and Regulations) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line (Standards and Regulations) | 18x 0.10 mm |
| Core diameter including insulation (Standards and Regulations) | 1.05 mm ±0.02 mm |
| Stripping length of the free conductor end (Key Commercial Data) | 50 mm |
| Smallest bending radius, fixed installation (Standards and Regulations) | 52 mm |
| Smallest bending radius, movable installation (Standards and Regulations) | 52 mm |
Technical specifications and performance data
Installation and operation guide