| Parameter | Value |
|---|---|
| GTIN | 4055626035383 |
| Orderkey | 1414907 |
| (Drawings) | |
| Catalog page | Page 298 (C-2-2019) |
| Packing unit | 1 pc |
| (Dimensions) | IP67 |
| Country of origin | PL (Poland) |
| ETIM 5.0 (eCl@ss) | EC001855 |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| REACh SVHC (Cable) | Lead 7439-92-1 |
| Custom tariff number | 85444290 |
| Contact material (General) | CuZn |
| Length of cable (Drawings) | 3 m |
| Material, knurls (General) | Zinc die-cast, nickel-plated |
| Coding (Ambient conditions) | M - Power |
| Torque (Ambient conditions) | 0.4 Nm (M12 connector) |
| (Standards and Regulations) | Resistant to salt water |
| eCl@ss 5.1 (Classifications) | 27061801 |
| eCl@ss 6.0 (Classifications) | 27279200 |
| eCl@ss 7.0 (Classifications) | 27279218 |
| eCl@ss 8.0 (Classifications) | 27279218 |
| eCl@ss 9.0 (Classifications) | 27060311 |
| Material of grip body (General) | PP |
| Degree of protection (Dimensions) | IP65 |
| Contact carrier material (General) | PA |
| Contact surface material (General) | Ni/Au |
| DiagramDerating diagram (Drawings) | |
| Rated voltage (Ambient conditions) | 690 V AC |
| Standards/specifications (Material) | M12 connector IEC 61076-2-111 |
| Status display (Ambient conditions) | No |
| Weight per Piece (excluding packing) | 460.000 g |
| Cable type (Standards and Regulations) | PUR halogen-free black |
| Wire colors (Standards and Regulations) | black 1, black 2, black 3, black 4, black 5, green/yellow |
| Acceleration (Standards and Regulations) | 10 m/s² |
| Cable weight (Standards and Regulations) | 144 kg/km |
| Degree of pollution (Ambient conditions) | 3 |
| Halogen-free (Standards and Regulations) | in accordance with DIN VDE 0472 part 815 |
| Number of positions (Ambient conditions) | 6 |
| UL AWM style (Standards and Regulations) | 20234 / 10492 (80°C/1000 V) |
| Overvoltage category (Ambient conditions) | III |
| Insulation resistance (Ambient conditions) | ≥ 100 MΩ |
| Standards/regulations (Ambient conditions) | M12 connector IEC 61076-2-111 |
| Rated current at 40°C (Ambient conditions) | 8 A |
| Traversing path (Standards and Regulations) | 10 m |
| Traversing rate (Standards and Regulations) | 3 m/s |
| AWG power supply (Standards and Regulations) | 16 |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 85 °C (Plug / socket) |
| Flame resistance (Standards and Regulations) | According to UL 758/1581 (Cable Flame) |
| Other resistance (Standards and Regulations) | Hydrolysis and microbe resistant as per VDE 0282 section 10 |
| Resistance to oil (Standards and Regulations) | according to DIN EN 60811-404, 168 h at 100 °C |
| Conductor material (Standards and Regulations) | Bare Cu litz wires |
| Test voltage, cable (Standards and Regulations) | ≥ 10000 V AC (Spark test) |
| Conductor resistance (Standards and Regulations) | ≤ 15 Ω/m (at 20 °C) |
| Flammability rating according to UL 94 (General) | V0 |
| Flammability rating according to UL 94 (Material) | V0 |
| Insulation resistance (Standards and Regulations) | ≥ 1 GΩ*km (at 20 °C) |
| Protective circuit/component (Ambient conditions) | unwired |
| Thickness, insulation (Standards and Regulations) | ≥ 0.36 mm |
| External sheath, color (Standards and Regulations) | black-gray RAL 7021 |
| Nominal voltage, cable (Standards and Regulations) | ≤ 1000 V AC |
| Outer sheath thickness (Standards and Regulations) | approx. 1.15 mm |
| Outer sheath, material (Standards and Regulations) | PUR |
| Conductor cross section (Standards and Regulations) | 6x 1.5 mm² |
| Number of bending cycles (Standards and Regulations) | 4000000 |
| Cable type (abbreviation) (Standards and Regulations) | PUR |
| External cable diameter D (Standards and Regulations) | 9.75 mm ±0.25 mm |
| Material conductor insulation (Standards and Regulations) | PP |
| Ambient temperature (operation) (Standards and Regulations) | -30 °C ... 80 °C (cable, flexible installation) |
| Circuit diagramContact assignment of the M12 socket (Drawings) | |
| Core diameter including insulation (Standards and Regulations) | 2.35 mm ±0.05 mm |
| Conductor structure, voltage supply (Standards and Regulations) | 78x 0.15 mm |
| Minimum bending radius, fixed installation (Standards and Regulations) | 5 x D |
| Minimum bending radius, flexible installation (Standards and Regulations) | 10 x D |
| Minimum bending radius, drag chain applications (Standards and Regulations) | 10 x D |
Technical specifications and performance data