| Parameter | Value |
|---|---|
| GTIN | 4055626746203 |
| (Cable) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Orderkey | 1069456 |
| Packing unit | 1 |
| (Dimensions) | IP67 |
| ETIM 5.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001262 |
| China RoHS (Cable) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Cable) | |
| Custom tariff number | 85444290 |
| (Ambient conditions) | 30 V DC |
| Contact material (General) | CuZn |
| Material, knurls (General) | Zinc die-cast, nickel-plated |
| Sealing material (General) | NBR |
| Coding (Ambient conditions) | A - standard |
| (Standards and Regulations) | max. 700 V AC (Data cable) |
| eCl@ss 7.0 (Classifications) | 27060308 |
| eCl@ss 8.0 (Classifications) | 27279218 |
| eCl@ss 9.0 (Classifications) | 27060308 |
| Material of grip body (General) | TPU, hardly inflammable, self-extinguishing |
| Degree of protection (Dimensions) | IP65 |
| Contact carrier material (General) | TPU GF |
| Contact surface material (General) | Ni/Au |
| Rated voltage (Ambient conditions) | 30 V AC |
| Status display (Ambient conditions) | No |
| Length of cable (Key Commercial Data) | 20 m |
| Shielding (Standards and Regulations) | Tinned copper-braided shield, approx. 85% covering |
| Cable type (Standards and Regulations) | VARAN |
| Color handle area (Ambient conditions) | black |
| Wire colors (Standards and Regulations) | Brown, blue, white/orange, white/green, green, orange |
| Acceleration (Standards and Regulations) | 2 m/s² |
| Cable weight (Standards and Regulations) | 81 kg/km |
| Degree of pollution (Ambient conditions) | 3 |
| Halogen-free (Standards and Regulations) | in accordance with DIN EN 50267-2-1 |
| Number of positions (Ambient conditions) | 6 |
| Overall twist (Standards and Regulations) | 1 star quad and 2 wires with 2 fillers |
| Overvoltage category (Ambient conditions) | II |
| Signal type/category (Ambient conditions) | VARAN, 100 Mbps |
| Bending radius (Standards and Regulations) | 93 mm |
| Insulation resistance (Ambient conditions) | ≥ 100 MΩ |
| Wave impedance (Standards and Regulations) | 100 Ω ±15 % |
| AWG signal line (Standards and Regulations) | 24 |
| Cable structure (Standards and Regulations) | 1x2xAWG22/19 + 1x4xAWG24/19 |
| Rated current at 40°C (Ambient conditions) | 2 A |
| Traversing path (Standards and Regulations) | 2 m |
| Traversing rate (Standards and Regulations) | 1 m/s |
| AWG power supply (Standards and Regulations) | 22 |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 90 °C (Plug / socket) |
| Material, filler (Standards and Regulations) | Yarn |
| Cable abbreviation (Standards and Regulations) | Li9YD12Y |
| Conductor material (Standards and Regulations) | Bare Cu litz wires |
| Test voltage, cable (Standards and Regulations) | 2000 V (Power supply) |
| Working capacitance (Standards and Regulations) | 50 nF (Data cable) |
| Conductor resistance (Standards and Regulations) | 77 Ω/m (Data cable) |
| Flammability rating according to UL 94 (General) | HB |
| Flammability rating according to UL 94 (Material) | HB |
| Insulation resistance (Standards and Regulations) | 5 GΩ*km (Data cable) |
| External sheath, color (Standards and Regulations) | black RAL 9005 |
| Material, inner sheath (Standards and Regulations) | TPE |
| Nominal voltage, cable (Standards and Regulations) | 125 V (Data cable) |
| Outer sheath, material (Standards and Regulations) | SANTOPRENE halogen-free |
| Type of pair shielding (Standards and Regulations) | Tinned copper braided shield, 95 % covering |
| Conductor cross section (Standards and Regulations) | 4x 0.25 mm² (Signal line) |
| Number of bending cycles (Standards and Regulations) | 3000000 |
| Cable type (abbreviation) (Standards and Regulations) | 970 |
| External cable diameter D (Standards and Regulations) | 7.8 mm ±0.2 mm |
| Material conductor insulation (Standards and Regulations) | PP |
| Ambient temperature (operation) (Standards and Regulations) | -20 °C ... 80 °C (Cable) |
| Conductor structure signal line (Standards and Regulations) | 19x 0.13 mm |
| Core diameter including insulation (Standards and Regulations) | 1.35 mm (Signal line) |
| Conductor structure, voltage supply (Standards and Regulations) | 19x 0.16 mm |
| Stripping length of the free conductor end (Key Commercial Data) | 50 mm |
| Transmission characteristics (category) (Standards and Regulations) | CAT5 (IEC 11801:2002) |
| Smallest bending radius, fixed installation (Standards and Regulations) | ≥ 93 mm |
| Smallest bending radius, movable installation (Standards and Regulations) | ≥ 93 mm |
Technical specifications and performance data
Installation and operation guide