| Parameter | Value |
|---|---|
| GTIN | 4046356920506 |
| Note | Made to Order (non-returnable) |
| (Cable) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Orderkey | 1411026 |
| (Material) | -20 °C ... 80 °C (cable, flexible installation) |
| Packing unit | 1 pc |
| (Dimensions) | IP67 |
| Country of origin | PL (Poland) |
| China RoHS (Cable) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Cable) | Lead 7439-92-1 |
| Custom tariff number | 85444290 |
| Shielding (Material) | Tinned copper braided shield |
| (Ambient conditions) | DeviceNet™ |
| Cable type (Material) | CAN Bus/DeviceNet |
| Attenuation (Material) | ≤ 22.9 dB/km (with 1 MHz) |
| Minimum order quantity | 50 pc |
| Wire colors (Material) | Red-black, blue-white |
| Acceleration (Material) | 3 m/s² |
| Cable weight (Material) | 90 kg/km |
| Halogen-free (Material) | in accordance with DIN VDE 0472 part 815 |
| UL AWM style (Material) | 21198 (80°C/300 V) |
| Overall twist (Material) | 2 pairs around a drain wire in the center to the core |
| Twisted pairs (Material) | 2 cores to the pair |
| Bending radius (Material) | 70 mm |
| Cable capacity (Material) | nom. 40 nF/km (Data cable) |
| Wave impedance (Material) | 120 Ω ±10 % (with 1 MHz) |
| AWG signal line (Material) | 24 |
| Cable structure (Material) | 2xAWG24/19+2xAWG22/19 |
| Contact material (General) | CuSn |
| Loop resistance (Material) | ≤ 181.80 Ω/km (Data cable) |
| Material, knurls (General) | Nickel-plated brass |
| Sealing material (General) | NBR |
| Traversing path (Material) | 4.5 m |
| Traversing rate (Material) | 3 m/s |
| AWG power supply (Material) | 22 |
| Coding (Ambient conditions) | A - standard |
| Flame resistance (Material) | UL 1581, Sec. 1060 (FT-1) |
| Other resistance (Material) | Low adhesion |
| Torque (Ambient conditions) | 0.4 Nm (M12 connector) |
| Conductor material (Material) | Tin-plated Cu litz wires |
| Material of grip body (General) | TPU, hardly inflammable, self-extinguishing |
| Insulation resistance (Material) | ≥ 5 GΩ*km (Data cable) |
| Degree of protection (Dimensions) | IP65 |
| External sheath, color (Material) | violet RAL 4001 |
| Nominal voltage, cable (Material) | ≤ 300 V (Peak value, not for high-power applications) |
| Outer sheath, material (Material) | PUR |
| Test voltage Core/Core (Material) | 2000 V (50 Hz, 1 min.) |
| Type of pair shielding (Material) | Plastic-coated aluminum foil, aluminum side outside |
| Conductor cross section (Material) | 2x 0.25 mm² (Data cable) |
| Contact carrier material (General) | TPU GF |
| Contact surface material (General) | Ni/Au |
| Optical shield covering (Material) | 80 % |
| Rated voltage (Ambient conditions) | 48 V AC |
| Number of bending cycles (Material) | 5000000 |
| Status display (Ambient conditions) | No |
| Test voltage Core/Shield (Material) | 2000 V (50 Hz, 1 min.) |
| Cable type (abbreviation) (Material) | 920 |
| External cable diameter D (Material) | 6.7 mm ±0,3 mm |
| Weight per Piece (excluding packing) | 39.100 g |
| Length of cable (Key Commercial Data) | 0.1 m |
| Material conductor insulation (Material) | Foamed PE (Data cable) |
| Number of positions (Ambient conditions) | 5 |
| Signal type/category (Ambient conditions) | CANopen® |
| Ambient temperature (operation) (Material) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line (Material) | 19x 0.13 mm |
| Insulation resistance (Ambient conditions) | ≥ 100 MΩ |
| Rated current at 40°C (Ambient conditions) | 4 A |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 90 °C (Plug / socket) |
| Core diameter including insulation (Material) | 1.95 mm ±0.05 mm (Data cable) |
| Conductor structure, voltage supply (Material) | 19x 0.15 mm |
| Minimum bending radius, fixed installation (Material) | 5 x D |
| Minimum bending radius, flexible installation (Material) | 10 x D |
| Minimum bending radius, drag chain applications (Material) | 10 x D |
| Stripping length of the free conductor end (Key Commercial Data) | 50 mm |