| Parameter | Value |
|---|---|
| DeviceNet™ | |
| Shielded | Yes |
| Screening | Tinned Copper Wire Mesh |
| Bus system | CANopen®/DeviceNet™ |
| Cable type | CANopen®/DeviceNet™, Outdoor, FRNC, Black |
| Pair wiring | 2 conductors as pair |
| Plug Cycles | ≥ 100 |
| Sensor Type | CANopen® |
| application | Outdoor spaces |
| Abbreviation | LI2XCHX02XS |
| Cable Weight | 70 kg/km |
| Cable length | 0.64 m |
| Codification | to |
| Construction | M12 Straight Connector |
| Line Section | 2x 0.25 mm² (Signal) |
| Product Type | Ready-made data cable |
| UL AWM Style | 21281 (80°C/300V) |
| Encoding Type | A (Standard) |
| Total cabling | 2 pairs around a reference conductor in the center as the core |
| Oil Resistance | Yes |
| Self-impedance | 120 Ω ±12 Ω (f = 1 MHz) |
| Serviceability | 39.8 nF (with 1 kHz, wire/wire) |
| AWG Signal Line | 24 |
| Cable Structure | 2xAWG24/19+2xAWG22/19 |
| Gasket material | FPM |
| Line Resistance | 90 Ω/km (Signal) |
| Number of poles | 5 |
| Contact material | CuSn |
| Dimension Scheme | |
| Flame Resistance | according to IEC 60332-3-25 (Cat. D) |
| Protection Index | IP65 |
| Rules/Provisions | IEC 61076-2-101 |
| Other resistances | UV resistant |
| Outer Wrap, Color | black |
| Status Indication | No |
| AWG Voltage Supply | 22 |
| Contact resistance | ≤ 5 mΩ |
| Grip body material | PP |
| Nominal Current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Protection Circuit | Unplugged |
| Absence of halogens | Yes |
| Conductive Material | Tinned Cu Conductor |
| Degree of pollution | 3 |
| Pair Shielding Type | Aluminum-coated blade |
| Signal Transit Time | 4.46 ns/m |
| Transmission Medium | copper |
| Visual Screen Cover | 70 % |
| Cable Outer Diameter | 6.9 mm ±0.3 mm |
| Outer Wrap, Material | FRNC |
| Signal Type/Category | CANopen® |
| Single Driver, Color | red-black, blue-white |
| Insulation resistance | ≥ 100 MΩ |
| Nominal Voltage Cable | ≤ 300 V |
| Number of Cable Outlets | 1 |
| Contact Support Material | PP |
| Denomination of standard | M12 plug-in connector |
| Cable Type (abbreviation) | 92X |
| Material: Contact Surface | Ni/AU |
| Screw connection material | Stainless steel |
| Wall Thickness Insulation | 0.6 mm (Signal) |
| Wall Thickness Outer Wrap | 1.15 mm |
| Line Insulation Resistance | ≥ 200 MΩ*km (at 20 °C) |
| Available Status Indication | No |
| Ambient Temperature (Service) | -40 °C ... 105 °C |
| Minimum bending radius, fixed | 5 x D |
| Material: Conductor Insulation | EP |
| Test Voltage Conductor/Display | 2000 V (50 Hz, 1 min.) |
| Test Voltage Conductor/Conductor | 2000 V (50 Hz, 1 min.) |
| Conductor Construction Signal Cable | 19x 0.13 mm |
| Conductor diameter incl. insulation | 1.9 mm (Signal) |
| Flammability class according to UL 94 | V0 |
| Minimum bending radius, flexibly positioned | 10 x D |
| Conductor Construction of Voltage Power Supply | 19x 0.16 mm |
Technical specifications and performance data