Key Specifications
GTIN:4046356413404
(Cable):No hazardous substances above threshold values
Orderkey:1435030
Catalog page:Page 246 (C-2-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356413404
(Cable)No hazardous substances above threshold values
Orderkey1435030
Catalog pagePage 246 (C-2-2017)
Packing unit1 pc
(Dimensions)IP67
Country of originPL (Poland)
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
Custom tariff number85444290
(Ambient conditions)0.6 Nm (Valve connector)
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)TPU (Seal molded)
Coding (Ambient conditions)A - standard
Torque (Ambient conditions)0.4 Nm (M12 connector)
(Standards and Regulations)-20 °C ... 80 °C (cable, flexible installation)
Material of grip body (General)TPU
Standard designation (Material)Valve connector
Standards/regulations (Material)EN 175301-803
Degree of protection (Dimensions)IP65
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)24 V AC
Status display (Ambient conditions)2 LEDs
Weight per Piece (excluding packing)49.000 g
Length of cable (Key Commercial Data)0.3 m
Material housing valve plug (General)TPU
Valve plug contact material (General)CuSn
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)Black 1, black 2, black 3, black 4, green/yellow
Acceleration (Standards and Regulations)30 m/s²
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)5
UL AWM style (Standards and Regulations)20549
Overall twist (Standards and Regulations)5 cores, twisted
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)50 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)20
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)0.9 m
Traversing rate (Standards and Regulations)5 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)in accordance with DIN UL-Style 20549
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Valve plug contact insert material (General)PA 6
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Valve plug contact surface material (General)Sn
Cable abbreviation (Standards and Regulations)Li9Y11Y-HF
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)≥ 1200 V
Conductor resistance (Standards and Regulations)39 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)V0
Insertion/withdrawal cycles (Ambient conditions)≥ 100 (M12 connector)
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)min. 20 MΩ*km
Protective circuit/component (Ambient conditions)unwired
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V
Outer sheath, material (Standards and Regulations)PUR
Central screw valve connector (Key Commercial Data)M3 x 29
Conductor cross section (Standards and Regulations)5x 0.5 mm²
Number of bending cycles (Standards and Regulations)15000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)5.3 mm ±0.02 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)28x 0.15 mm
Core diameter including insulation (Standards and Regulations)1.5 mm ±0.05 mm (Signal line)
Smallest bending radius, fixed installation (Standards and Regulations)26.5 mm
Smallest bending radius, movable installation (Standards and Regulations)53 mm

Product Description

Sensor/actuator cable, 5-pole halogen-free, M12 straight connector, coding: A SPEEDCON, with 2 LEDs, to AD valve connectors (Druckschalter), with 2 LEDs, cable length: 0.3 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top