| Parameter | Value |
|---|---|
| 60 V DC | |
| Type | Plug straight M12 |
| Coding | B |
| General | Further products with variable cable type and variable cable length can be found in the accessories section |
| Shielded | yes |
| Bus system | INTERBUS |
| Cable type | INTERBUS [900] |
| Application | Standard |
| Coding type | B (inverse) |
| Sensor type | INTERBUS |
| Cable length | 2 m |
| Cable weight | 70 kg/km |
| Product type | Data cable preassembled |
| Signal speed | 0.66 c |
| Overall twist | 3 pairs to the core |
| Twisted pairs | 2 cores to the pair |
| Cable capacity | ≤ 60 nF/km (At 800 Hz) |
| Status display | no |
| Wave impedance | 120 Ω ±20 % (at 64 kHz) |
| AWG signal line | 24 |
| Loop resistance | ≤ 159.80 Ω/km |
| Contact material | CuSn |
| Flame resistance | according to VDE 0472, Part 4, test type B |
| Conductor material | Bare Cu litz wires |
| Nominal current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Shield attenuation | ≤ 15 dB/km (at 256 kHz) |
| Single wire, color | green-yellow, white-brown, gray-pink |
| Conductor structure | 3 x 2 x 0.22 mm² |
| Coupling resistance | < 250.00 mΩ/m (at 30 MHz) |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 5 |
| Transmission medium | Copper |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Signal type/category | INTERBUS, 16 Mbps |
| Insulation resistance | ≥ 100 MΩ |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| External sheath, color | may green RAL 6017 |
| Nominal voltage, cable | 250 V (Peak value, not for high-power applications) |
| Outer sheath, material | PUR |
| Status display present | No |
| Test voltage Core/Core | 1500 Vrms |
| Conductor cross section | 3x 2x 0.22 mm² |
| External cable diameter | 8.00 mm |
| Contact carrier material | PA 6.6 |
| Contact surface material | Ni/Au |
| Material wire insulation | PE |
| Test voltage Core/Shield | 1000.00 Vrms |
| Insertion/withdrawal cycles | ≥ 100 |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 32x 0.10 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000000, Bending radius: 120 mm, Traversing path: 10 m, Traversing rate: 1.6 m/s, Acceleration: 3.2 m/s² |
| Near end crosstalk attenuation (NEXT) | ≥ 61 dB (at 772 kHz) |
| Flammability rating according to UL 94 | V0 |
| Minimum bending radius, fixed installation | 7.5 x D |
| Smallest bending radius, fixed installation | 60 mm |
| Minimum bending radius, flexible installation | 15 x D |
| Smallest bending radius, movable installation | 120 mm |
| Contact Color (signal designation) Contact (optional) | 1 (Plug) YE (DO) |
Technical specifications and performance data
Installation and operation guide