| Parameter | Value |
|---|---|
| GTIN | Four trillion forty six billion three hundred fifty six million five hundred seventy six thousand six hundred seventy three |
| (Size) | IP67 |
| (Cable) | Any hazardous substances above the threshold values |
| Sales key | BF1CKA - |
| Pieces/pack. | 1 PCS |
| UNSPSC 11 (ETIM) | Thirty one million two hundred fifty one thousand five hundred one |
| ETIM 3.0 (eCl@ss) | EC001855 |
| ETIM 4.0 (eCl@ss) | EC001855 |
| ETIM 5.0 (eCl@ss) | EC001855 |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| China RoHS (Cable) | Period for proper use: unlimited = EFUP-and |
| UNSPSC 13.2 (ETIM) | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 6.01 (ETIM) | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 12.01 (ETIM) | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 7.0901 (ETIM) | Thirty one million two hundred fifty one thousand five hundred one |
| Number customs tariff | Eighty five million four hundred forty four thousand two hundred ninety |
| eCl@ss 4.0 (Rankings) | Twenty seven million sixty thousand three hundred six |
| eCl@ss 4.1 (Rankings) | Twenty seven million sixty thousand three hundred six |
| eCl@ss 5.0 (Rankings) | Twenty seven million sixty one thousand eight hundred one |
| eCl@ss 5.1 (Rankings) | Twenty seven million sixty one thousand eight hundred |
| eCl@ss 6.0 (Rankings) | Twenty seven million two hundred seventy nine thousand two hundred |
| eCl@ss 7.0 (Rankings) | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 8.0 (Rankings) | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 9.0 (Rankings) | Twenty seven million sixty thousand three hundred eleven |
| Nut material (General) | Zinc die-cast, nickel-plated |
| The code for the order | One million four hundred forty five thousand fifty nine |
| Material gasket (General) | NBR |
| Contact material (General) | CuSn |
| Material handles (General) | TPU, hardly inflammable, self-extinguishing |
| (Environmental conditions) | 60 V DC |
| Degree of protection (Size) | IP65 |
| (Regulations and requirements) | -25 °C ... 80 °C (cable, mobile installation) |
| Insert material latch (General) | TPU GF |
| Length. cable (Commercial data) | 7.5 m |
| Material surface contacts (General) | Ni/Au |
| Weight per piece (package included) | 380,000 g |
| Ambient temperature (operation) (Size) | -25 °C ... 90 °C (plug / connector female) |
| N. of poles (Environmental conditions) | Five |
| Shielding (Regulations and requirements) | Wire braid tinned copper |
| Cable type (Regulations and requirements) | EVEN without halogenated black |
| Color wire (Regulations and requirements) | brown, white, blue, black, grey |
| Rating voltage (Environmental conditions) | 48 V AC |
| Bend radius (Regulations and requirements) | 52 mm |
| Acceleration (Regulations and requirements) | 10 m/s2 |
| Pollution degree (Environmental conditions) | Three |
| UL AWM Style (Regulations and requirements) | Twenty thousand five hundred forty nine |
| Class behaviour according to UL 94 (General) | HB |
| Class behaviour according to UL 94 (Material) | HB |
| Lay the entire (Regulations and requirements) | 5 wires around filler to the soul |
| Oil resistance (Regulations and requirements) | in accordance with DIN EN 60811-2-1 |
| Signal line AWG (Regulations and requirements) | Twenty two |
| Flame resistance (Regulations and requirements) | according to the UL 758/1581 FT2 |
| Overvoltage category (Environmental conditions) | II |
| Signalling status of (Environmental conditions) | No |
| Special features (Regulations and requirements) | drag chain |
| Insulation resistance (Environmental conditions) | ≥ 100 MΩ |
| Positioning speed (Regulations and requirements) | 3 m/s |
| Abbreviation cables (Regulations and requirements) | LiF9YC11Y |
| Rated current at 40 ℃ (Environmental conditions) | 4 To |
| Cover screen optical (Regulations and requirements) | 80 % |
| Positioning movement (Regulations and requirements) | 10 m |
| The other resistance (Regulations and requirements) | Resistance to hydrolysis and microbes |
| Insulation resistance (Regulations and requirements) | 70 GΩ*km (at 20 °C) |
| Cable outer diameter D (Regulations and requirements) | 5.25 mm ±0.2 mm |
| External sheath, color (Regulations and requirements) | grey-black RAL 7021 |
| Outer sheath, material (Regulations and requirements) | WHILE |
| Rated voltage of cable (Regulations and requirements) | 300 V (20 °C) |
| Test voltage wire/wire (Regulations and requirements) | 3000 V (at 20 °C) |
| Conductor cross section (Regulations and requirements) | 5x 0.34 mm2 (signal Line) |
| Number of operating cycles, (Environmental conditions) | ≥ 100 |
| The absence of halogens (Regulations and requirements) | according to DIN VDE 0472 Part 815 |
| The conductive material (Regulations and requirements) | Cu wire bare |
| Material insulation wire (Regulations and requirements) | PP |
| Cable type (abbreviation) (Regulations and requirements) | WHILE |
| Minimum bend radius, fixed (Regulations and requirements) | 26 mm |
| Tree conductor signal line (Regulations and requirements) | 42x 0.10 mm |
| Minimum bend radius, mobile (Regulations and requirements) | 52 mm (up to +60 ℃) |
| resistance of the conductor (Regulations and requirements) | max. 57 Ω/km (at 20 °C) |
| Ambient temperature (operation) (Regulations and requirements) | -40 °C ... 80 °C (cable, fixed installation) |
| The number of cycles of bending (Regulations and requirements) | Ten million |
| Wire diameter including insulation (Regulations and requirements) | 1.27 mm ±0.02 mm (signal Line) |
Technical specifications and performance data