Service time: Monday to Friday 9:00-18:00
SAC-5P-M12MS/ 5,0-PVC SH - SAC-5P-M12MS/ 5,0-PVC SH 1426507 PHOENIX CONTACT Cable for sensors/actuators 5-pin, PVC, black RAL 9005, shi..
In Stock Hot Product

SAC-5P-M12MS/ 5,0-PVC SH

SAC-5P-M12MS/ 5,0-PVC SH 1426507 PHOENIX CONTACT Cable for sensors/actuators 5-pin, PVC, black RAL 9005, shi..

$0.00USD
4641 in stock
Key Specifications
EAN:Four trillion fifty five billion six hundred twenty six million four hundred sixty two thousand two hundred nineteen
(Cable):No dangerous substances above the thresholds
Key order:One million four hundred twenty six thousand five hundred seven
Key selling:BF1CKA -
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EANFour trillion fifty five billion six hundred twenty six million four hundred sixty two thousand two hundred nineteen
(Cable)No dangerous substances above the thresholds
Key orderOne million four hundred twenty six thousand five hundred seven
Key sellingBF1CKA -
Packing unit1 pcs
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Space of time for the intended use: unlimited = FEUP-e
Tariff number tariffEighty five million four hundred seventy two thousand
eCl@ss 6.0 (Ratings)Twenty seven million two hundred seventy nine thousand two hundred
eCl@ss 7.0 (Ratings)Twenty seven million two hundred seventy nine thousand two hundred eighteen
eCl@ss 9.0 (Ratings)Twenty seven million sixty thousand three hundred eleven
Minimum order quantity50 pcs
(Environmental conditions)60 V DC
Material contact (Overview)CuSn
Material knurled (Overview)Die-cast zinc, nickel plated
Name of standard (Material)Plug-in connector M12
Material body grip (Overview)TPU fire-retardant, self-extinguishing
Cable length (Data commercial)5 m
(Standards and specifications)-5 °C ... 80 °C (cable, available mobile)
Material of the board (Overview)NBR
Unit weight (excluding packaging)302,500 g
Encoding (Environmental conditions)A - standard
Material contact surface (Overview)Ni/Au
Standards/specifications (Material)IEC 61076-2-101
Room temperature (service) (Measures)-25 °C ... 90 °C (male / female)
Material support of contacts (Overview)TPU GF
Shielding (Standards and specifications)Mesh of copper wires tinned
Category surge (Environmental conditions)II
Cycles of plug (Environmental conditions)≥ 100
Tension sizing (Environmental conditions)48 V AC
Number of poles (Environmental conditions)Five
Pollution degree (Environmental conditions)Three
Cabling total (Standards and specifications)5 drivers around padding as soul
Colors driver (Standards and specifications)Brown, white, blue, black, grey
Status indication (Environmental conditions)Not
Type of cable (Standards and specifications)Black PVC
Filling Material (Standards and specifications)PVC
Flame resistance (Standards and specifications)according to UL-Style 2464
Signal cable AWG (Standards and specifications)Twenty two
Insulation resistance (Environmental conditions)≥ 100 MΩ
Outer wrap, color (Standards and specifications)black RAL 9005
Section of driver (Standards and specifications)5x 0,34 mm2 (driver signals)
Test voltage Cable (Standards and specifications)≥ 3000 V
Conductive Material (Standards and specifications)Conductor Cu bare
Cover visual screen (Standards and specifications)85 %
Rated voltage Cable (Standards and specifications)≤ 300 V
Weight of the cable (Standards and specifications)55 kg/km
Class of flammability according to UL 94 (Material)HB
Class of flammability according to UL 94 (Overview)HB
Current sizing at 40 °C (Environmental conditions)4 To
Standards/specifications (Environmental conditions)Plug-in connector M12 to IEC 61076-2-101
Insulation resistance (Standards and specifications)≥ 10 MΩ*km (at 20 °C)
Outer casing, material (Standards and specifications)PVC
Cable type (abbreviation) (Standards and specifications)PVC
Outer diameter of cable D (Standards and specifications)To 5.9 mm ±0.2 mm
Room temperature (service) (Standards and specifications)-25 °C ... 80 °C (cable, fixed)
Resistance of the conductor (Standards and specifications)≤ 58 Ω/km (at 20 °C)
Thickness of wall Insulation (Standards and specifications)≥ 0.23 mm (Insulated conductor)
Material Insulation conductor (Standards and specifications)PVC
Protective circuit/component protection (Environmental conditions)without connect
Construction of the driver signal cable (Standards and specifications)42x 0.10 mm
Diameter of the conductors, insulation included (Standards and specifications)1,35 mm ±0.02 mm

Product Description

Sensor/actuator cable, 5-pole, PVC, black RAL 9005, shielded, M12 straight male connector, coding: A, to free cable end, cable length: 5 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Cable for sensors/actuators 5-pin, PVC, black RAL 9005, shielded, Plug straight M12, coded A, end of free cable, cable length: 5 m

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top