Service time: Monday to Friday 9:00-18:00
SAC-5P-M12MS/5,0-PUR - SAC-5P-M12MS/5,0-PUR 1669783 PHOENIX CONTACT Sensor/actuator cable
In Stock Hot Product

SAC-5P-M12MS/5,0-PUR

SAC-5P-M12MS/5,0-PUR 1669783 PHOENIX CONTACT Sensor/actuator cable

$18.38USD
574 in stock
Key Specifications
GTIN:4017918134686
(Cable):No hazardous substances above threshold values
Orderkey:1669783
Catalog page:Page 207 (C-2-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918134686
(Cable)No hazardous substances above threshold values
Orderkey1669783
Catalog pagePage 207 (C-2-2017)
Packing unit1 pc
(Dimensions)IP68
Country of originIN (India)
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
Custom tariff number85444290
(Ambient conditions)60 V DC
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
Torque (Ambient conditions)0.4 Nm (M12 connector)
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Degree of protection (Dimensions)IP65
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Weight per Piece (excluding packing)164.000 g
Length of cable (Key Commercial Data)5 m
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)brown, white, blue, black, green-yellow
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)35 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)5
UL AWM style (Standards and Regulations)20549 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations)5 wires around filler to the core
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)50 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)22
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)in accordance with DIN UL-Style 20549
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)Li9Y11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)3000 V
Conductor resistance (Standards and Regulations)max. 58 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 16 GΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
Thickness, insulation (Standards and Regulations)≥ 0.21 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)300 V
Outer sheath thickness (Standards and Regulations)approx. 0.7 mm
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)5x 0.34 mm² (Signal line)
Number of bending cycles (Standards and Regulations)4000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)5 mm ±0.15 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.27 mm ±0.02 mm (Signal line)
Stripping length of the free conductor end (Key Commercial Data)50 mm
Smallest bending radius, fixed installation (Standards and Regulations)25 mm
Smallest bending radius, movable installation (Standards and Regulations)50 mm

Product Description

Sensor/actuator cable, 5-pole, halogen-free PUR, grayish black RAL 7021, Straight male connector M12, coding: A, to free cable end, cable length: 5 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top