SAC-5P-M12MS/2,0-810/M12FS - SAC-5P-M12MS/2,0-810/M12FS 1416137 PHOENIX CONTACT Sensor/actuator cable
In Stock Hot Product

SAC-5P-M12MS/2,0-810/M12FS

SAC-5P-M12MS/2,0-810/M12FS 1416137 PHOENIX CONTACT Sensor/actuator cable

$0.00USD
3869 in stock
Key Specifications
GTIN:4055626063751
(Cable):No hazardous substances above threshold values
Orderkey:1416137
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626063751
(Cable)No hazardous substances above threshold values
Orderkey1416137
Packing unit1 pc
(Dimensions)IP68
Country of originPL (Poland)
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
Custom tariff number85444290
(Ambient conditions)60 V DC
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
Torque (Ambient conditions)0.4 Nm (M12 connector)
(Standards and Regulations)≤ 60 °C (cable, drag chain applications)
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Standard designation (Material)M12 connector
Note (Standards and Regulations)Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Standards/regulations (Material)IEC 61076-2-101
Degree of protection (Dimensions)IP65
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Weight per Piece (excluding packing)132.500 g
Length of cable (Key Commercial Data)2 m
Cable type (Standards and Regulations)PUR, halogen-free, highly flexible, welding-sputter resistant, orange
Wire colors (Standards and Regulations)brown, white, blue, black, green-yellow
Acceleration (Standards and Regulations)10 m/s²
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)5
UL AWM style (Standards and Regulations)20549 (80°C/300 V)
Overall twist (Standards and Regulations)5 wires around filler to the core
Overvoltage category (Ambient conditions)II
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)22
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)in acc. with UL FT-2
Other resistance (Standards and Regulations)hydrolysis and microbe resistant
Cable abbreviation (Standards and Regulations)LiF9Y11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Sheath resistant to welding beads, can be recycled, matt, without adhesion, wear-resistant, flame resistant and self-extinguishing
Conductor resistance (Standards and Regulations)approx. 57 Ω/km
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 20 MΩ*km
Protective circuit/component (Ambient conditions)unwired
External sheath, color (Standards and Regulations)orange RAL 2003
Nominal voltage, cable (Standards and Regulations)300 V (Peak value, not for high-power applications)
Outer sheath, material (Standards and Regulations)PUR
Test voltage Core/Core (Standards and Regulations)3000 V (Spark test)
Conductor cross section (Standards and Regulations)5x 0.34 mm²
Number of bending cycles (Standards and Regulations)5000000
Cable type (abbreviation) (Standards and Regulations)810
External cable diameter D (Standards and Regulations)6.9 mm ±0.1 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.55 mm ±0.05 mm (Signal line)
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

Sensor/actuator cable, 5-pole, halogen-free PUR, resistant to solder splashes, orange RAL 2003, M12 straight male connector, coding: A, to M12 straight connection female, coding: A, cable length: 2 m,
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top