

| Parameter | Value |
|---|---|
| 15000000 | |
| Note | Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments. |
| Type | Plug straight M12 |
| Shielded | no |
| Cable type | PUR halogen-free highly flexible resistant to welding sparks gray 5th conductor green/yellow [802] |
| Coding type | A |
| Cable length | 2 m |
| Halogen-free | The cable is halogen-free |
| Product type | Sensor/actuator cable |
| Test voltage | 1200 V |
| UL AWM Style | 20549 |
| Overall twist | 5 wires around filler to the core |
| Torsion force | ± 360 °/m |
| Torsion cycles | 1000000 |
| AWG signal line | 22 |
| Flame resistance | in accordance with UL 758/1581 FT2 |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Conductor material | Bare Cu litz wires |
| Nominal voltage UN | 24 V DC |
| Single wire, color | black, brown, blue, white, green/yellow |
| Special properties | Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing |
| Dimensional drawing | |
| Max. bending cycles | 10000000 |
| Number of positions | 5 |
| Insulation resistance | ≥ 20 MΩ*km |
| External sheath, color | gray RAL 7001 |
| Nominal voltage, cable | 300 V |
| Outer sheath, material | PUR |
| Conductor cross section | 5x 0.34 mm² (Signal line) |
| External cable diameter | 5.1 mm ±0.2 mm |
| Material wire insulation | PP |
| Max. conductor resistance | approx. 53 Ω/km |
| Wire diameter incl. insulation | 1.3 mm ±0.05 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 42x 0.10 mm |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 5 x D |
Technical specifications and performance data
Installation and operation guide