Service time: Monday to Friday 9:00-18:00
SAC-5P-M12MS/12-92X/M12FSSHOD - SAC-5P-M12MS/12-92X/M12FSSHOD 1423265 PHOENIX CONTACT Bus system cable SAC-5P-M12MS/12-92X/M12FSSHOD 1423265
In Stock Hot Product

SAC-5P-M12MS/12-92X/M12FSSHOD

SAC-5P-M12MS/12-92X/M12FSSHOD 1423265 PHOENIX CONTACT Bus system cable SAC-5P-M12MS/12-92X/M12FSSHOD 1423265

$0.00USD
3709 in stock
Key Specifications
GTIN:4055626337364
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1423265
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626337364
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1423265
Packing unit1
(Dimensions)DeviceNet™
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
Coding (Dimensions)A - standard
Custom tariff number85444290
Contact material (General)CuSn
Material, knurls (General)Stainless steel
Rated voltage (Dimensions)48 V AC
Sealing material (General)FPM
Status display (Dimensions)No
(Standards and Regulations)55 Ω/km (Power)
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)PP
Standard designation (Material)M12 connector
Degree of pollution (Dimensions)3
Number of positions (Dimensions)5
Standards/regulations (Material)IEC 61076-2-101
Signal type/category (Dimensions)CANopen®
Contact carrier material (General)PP
Contact surface material (General)Ni/Au
Standards/regulations (Dimensions)M12 connector IEC 61076-2-101
Rated current at 40°C (Dimensions)4 A
Length of cable (Key Commercial Data)12 m
Shielding (Standards and Regulations)Tinned copper braided shield
Cable type (Standards and Regulations)CAN bus/DeviceNet™, black
Wire colors (Standards and Regulations)Red-black, blue-white
Cable weight (Standards and Regulations)70 kg/km
Halogen-free (Standards and Regulations)yes
UL AWM style (Standards and Regulations)21281 (80°C/300 V)
Overall twist (Standards and Regulations)2 pairs around a drain wire in the center to the core
Protective circuit/component (Dimensions)unwired
Twisted pairs (Standards and Regulations)2 cores to the pair
Signal runtime (Standards and Regulations)4.46 ns/m
Wave impedance (Standards and Regulations)120 Ω ±12 Ω (f = 1 MHz)
AWG signal line (Standards and Regulations)24
Cable structure (Standards and Regulations)2xAWG24/19+2xAWG22/19
AWG power supply (Standards and Regulations)22
Flame resistance (Standards and Regulations)According to IEC 60332-3-25 (Cat. D)
Other resistance (Standards and Regulations)UV resistant
Resistance to oil (Standards and Regulations)yes
Cable abbreviation (Standards and Regulations)LI2XCHX02XS
Conductor material (Standards and Regulations)Tin-plated Cu litz wires
Working capacitance (Standards and Regulations)39.8 nF (at 1 kHz, core/core)
Conductor resistance (Standards and Regulations)90 Ω/km (Signal)
Flammability rating according to UL 94 (General)V0
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 200 MΩ*km (at 20 °C)
Thickness, insulation (Standards and Regulations)0.6 mm (Signal)
External sheath, color (Standards and Regulations)black
Nominal voltage, cable (Standards and Regulations)≤ 300 V
Outer sheath thickness (Standards and Regulations)1.15 mm
Outer sheath, material (Standards and Regulations)FRNC
Test voltage Core/Core (Standards and Regulations)2000 V (50 Hz, 1 min.)
Type of pair shielding (Standards and Regulations)Aluminum-lined foil
Conductor cross section (Standards and Regulations)2x 0.25 mm² (Signal)
Optical shield covering (Standards and Regulations)70 %
Test voltage Core/Shield (Standards and Regulations)2000 V (50 Hz, 1 min.)
Cable type (abbreviation) (Standards and Regulations)92X
External cable diameter D (Standards and Regulations)6.9 mm ±0,3 mm
Material conductor insulation (Standards and Regulations)PE
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 105 °C
Conductor structure signal line (Standards and Regulations)19x 0.13 mm
Core diameter including insulation (Standards and Regulations)1.9 mm (Signal)
Conductor structure, voltage supply (Standards and Regulations)19x 0.16 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D

Product Description

Bus System Cable, CANopen®, DeviceNet™, 5-pole, Halogen-free FRNC, black, shielded, M12 straight connector, encoding: A, to M12 straight female, encoding: A, cable length: 12 m, for outdoor applicatio
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Bus system cable, CANopen®, DeviceNet™, 5-position, FRNC halogen-free, black, shielded, cable length: 12 m, for outdoor applications, with high-grade steel knurl

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top