Service time: Monday to Friday 9:00-18:00
SAC-5P-M12MS/1,0-28X/M12FS OD - SAC-5P-M12MS/1,0-28X/M12FS OD 1057278 PHOENIX CONTACT Sensor/actuator cable SAC-5P-M12MS/1,0-28X/M12FS OD 10..
In Stock Hot Product

SAC-5P-M12MS/1,0-28X/M12FS OD

SAC-5P-M12MS/1,0-28X/M12FS OD 1057278 PHOENIX CONTACT Sensor/actuator cable SAC-5P-M12MS/1,0-28X/M12FS OD 10..

$0.00USD
3182 in stock
Key Specifications
GTIN:4055626698687
(Cable):No hazardous substances above threshold values
Orderkey:1057278
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626698687
(Cable)No hazardous substances above threshold values
Orderkey1057278
Packing unit1
(Dimensions)60 V DC
UNSPSC 11 (ETIM)31251501
ETIM 2.0 (eCl@ss)EC000830
ETIM 3.0 (eCl@ss)EC001855
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
UNSPSC 13.2 (ETIM)31251501
UNSPSC 6.01 (ETIM)31251501
Coding (Dimensions)A - standard
UNSPSC 12.01 (ETIM)31251501
Custom tariff number85444290
UNSPSC 7.0901 (ETIM)31251501
Contact material (General)CuSn
Material, knurls (General)Stainless steel
Rated voltage (Dimensions)48 V AC
Sealing material (General)FPM
Status display (Dimensions)No
(Standards and Regulations)20 °C ±5 °C (cable, drag chain applications)
eCl@ss 4.0 (Classifications)27060306
eCl@ss 4.1 (Classifications)27060306
eCl@ss 5.0 (Classifications)27061801
eCl@ss 5.1 (Classifications)27061801
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)PP
Standard designation (Material)M12 connector
Degree of pollution (Dimensions)3
Number of positions (Dimensions)5
Standards/regulations (Material)IEC 61076-2-101
Contact carrier material (General)PP
Contact surface material (General)Ni/Au
Insulation resistance (Dimensions)≥ 100 MΩ
Standards/regulations (Dimensions)M12 connector IEC 61076-2-101
Rated current at 40°C (Dimensions)4 A
Length of cable (Key Commercial Data)1 m
Cable type (Standards and Regulations)PE-X black
Wire colors (Standards and Regulations)Brown, white, blue, black, gray
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)70 kg/km
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Insertion/withdrawal cycles (Dimensions)≥ 100
Overall twist (Standards and Regulations)5 wires around filler to the core
Protective circuit/component (Dimensions)unwired
AWG signal line (Standards and Regulations)20
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Flame resistance (Standards and Regulations)According to DIN EN 60332-1-2
Material, filler (Standards and Regulations)PP yarn
Other resistance (Standards and Regulations)Resistance to fuels according to IEC 60811, 168 h at 70°C
Resistance to oil (Standards and Regulations)According to DIN EN 60811-2-1, 168 h at 100°C
Cable abbreviation (Standards and Regulations)Li2X2X
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Irradiated
Test voltage, cable (Standards and Regulations)≥ 3000 V AC (Spark test)
Conductor resistance (Standards and Regulations)≤ 39 Ω/m (at 20 °C)
Flammability rating according to UL 94 (General)V0
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 100 MΩ*km (at 20 °C)
Thickness, insulation (Standards and Regulations)approx. 0.3 mm (Core insulation)
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)≤ 300 V AC
Outer sheath thickness (Standards and Regulations)approx. 1.25 mm
Outer sheath, material (Standards and Regulations)PE-X
Conductor cross section (Standards and Regulations)5x 0.5 mm²
Number of bending cycles (Standards and Regulations)2000000
Cable type (abbreviation) (Standards and Regulations)28X
External cable diameter D (Standards and Regulations)6.8 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PE-X
Length of twist, overall twist (Standards and Regulations)68 mm
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 105 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)28x 0.15 mm
Core diameter including insulation (Standards and Regulations)1.6 mm ±0.5 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

Sensor/actuator cable, 5-pole, halogen-free PE-X, greyish black RAL 7021, M12 straight male connector, encoding: A, to M12 straight connection female, coding: A, cable length: 1 m, for outdoor applica
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 5-position, PE-X halogen-free, black-gray RAL 7021, Plug straight M12, A-coded, on Socket straight M12, A-coded, cable length: 1 m, for outdoor applications, with high-grade steel knurl

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top