Service time: Monday to Friday 9:00-18:00
SAC-5P-M12MS/0,45-920/8P-FS MG - SAC-5P-M12MS/0,45-920/8P-FS MG 1410053 PHOENIX CONTACT Bus system cable SAC-5P-M12MS/0,45-920/8P-FS MG 14100..
In Stock Hot Product

SAC-5P-M12MS/0,45-920/8P-FS MG

SAC-5P-M12MS/0,45-920/8P-FS MG 1410053 PHOENIX CONTACT Bus system cable SAC-5P-M12MS/0,45-920/8P-FS MG 14100..

$0.00USD
3746 in stock
Key Specifications
GTIN:4046356888660
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1410053
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356888660
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1410053
Packing unit1
(Dimensions)IP68
UNSPSC 11 (ETIM)31251501
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)
UNSPSC 13.2 (ETIM)31251501
UNSPSC 6.01 (ETIM)31251501
UNSPSC 12.01 (ETIM)31251501
Custom tariff number85444290
UNSPSC 7.0901 (ETIM)31251501
(Ambient conditions)60 V DC
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
(Standards and Regulations)-20 °C ... 80 °C (cable, flexible installation)
eCl@ss 4.0 (Classifications)27060306
eCl@ss 4.1 (Classifications)27060306
eCl@ss 5.0 (Classifications)27061801
eCl@ss 5.1 (Classifications)27061800
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Degree of protection (Dimensions)IP65
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)0.45 m
Shielding (Standards and Regulations)Tinned copper braided shield
Cable type (Standards and Regulations)CAN Bus/DeviceNet
Attenuation (Standards and Regulations)≤ 22.9 dB/km (with 1 MHz)
Wire colors (Standards and Regulations)Red-black, blue-white
Acceleration (Standards and Regulations)3 m/s²
Cable weight (Standards and Regulations)90 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)5
UL AWM style (Standards and Regulations)21198 (80°C/300 V)
Overall twist (Standards and Regulations)2 pairs around a drain wire in the center to the core
Overvoltage category (Ambient conditions)II
Twisted pairs (Standards and Regulations)2 cores to the pair
Bending radius (Standards and Regulations)70 mm
Cable capacity (Standards and Regulations)nom. 40 nF/km (Data cable)
Insulation resistance (Ambient conditions)≥ 100 MΩ
Wave impedance (Standards and Regulations)120 Ω ±10 % (with 1 MHz)
AWG signal line (Standards and Regulations)24
Cable structure (Standards and Regulations)2xAWG24/19+2xAWG22/19
Loop resistance (Standards and Regulations)≤ 181.80 Ω/km (Data cable)
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)4.5 m
Traversing rate (Standards and Regulations)3 m/s
AWG power supply (Standards and Regulations)22
Flame resistance (Standards and Regulations)UL 1581, Sec. 1060 (FT-1)
Other resistance (Standards and Regulations)Low adhesion
Conductor material (Standards and Regulations)Tin-plated Cu litz wires
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 5 GΩ*km (Data cable)
External sheath, color (Standards and Regulations)violet RAL 4001
Nominal voltage, cable (Standards and Regulations)≤ 300 V (Peak value, not for high-power applications)
Outer sheath, material (Standards and Regulations)PUR
Test voltage Core/Core (Standards and Regulations)2000 V (50 Hz, 1 min.)
Type of pair shielding (Standards and Regulations)Plastic-coated aluminum foil, aluminum side outside
Conductor cross section (Standards and Regulations)2x 0.25 mm² (Data cable)
Optical shield covering (Standards and Regulations)80 %
Number of bending cycles (Standards and Regulations)5000000
Test voltage Core/Shield (Standards and Regulations)2000 V (50 Hz, 1 min.)
Cable type (abbreviation) (Standards and Regulations)920
External cable diameter D (Standards and Regulations)6.7 mm ±0,3 mm
Material conductor insulation (Standards and Regulations)Foamed PE (Data cable)
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)19x 0.13 mm
Core diameter including insulation (Standards and Regulations)1.95 mm ±0.05 mm (Data cable)
Conductor structure, voltage supply (Standards and Regulations)19x 0.15 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D
Minimum bending radius, drag chain applications (Standards and Regulations)10 x D

Product Description

Bus system cable, 5-pole halogen-free, shielded, M12 straight connector, encoding: A, a M12 straight female, encoding: A, cable length: 0.45 m, 8-pole female connector
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Bus system cable, 5-position, PUR halogen-free, violet RAL 4001, shielded, Plug straight M12, A-coded, on Socket straight M12, A-coded, cable length: 0.45 m, Socket is 8-pos.

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top