Key Specifications
GTIN:4046356994903
Orderkey:1413223
(Drawings):
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356994903
Orderkey1413223
(Drawings)
Packing unit1
(Dimensions)60 V DC
ETIM 4.0 (eCl@ss)EC001855
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
UNSPSC 13.2 (ETIM)31251501
UNSPSC 19.0 (ETIM)31251501
UNSPSC 20.0 (ETIM)31251501
UNSPSC 21.0 (ETIM)31251501
Coding (Dimensions)A - standard
Custom tariff number85444290
Contact material (General)CuSn
Length of cable (Drawings)0.3 m
Material, knurls (General)Zinc die-cast, nickel-plated
Rated voltage (Dimensions)48 V AC
Status display (Dimensions)No
(Standards and Regulations)-25 °C ... 80 °C (cable, flexible installation)
eCl@ss 5.1 (Classifications)27061801
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Degree of pollution (Dimensions)3
Number of positions (Dimensions)5
Overvoltage category (Dimensions)II
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Insulation resistance (Dimensions)≥ 100 MΩ
Standards/regulations (Dimensions)M12 connector IEC 61076-2-101
Rated current at 40°C (Dimensions)4 A
Standards/specifications (Material)M12 connector IEC 61076-2-101
Shielding (Standards and Regulations)Tinned copper braided shield
Cable type (Standards and Regulations)PUR halogen-free black
Wire colors (Standards and Regulations)Brown, white, blue, black, gray
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)43 kg/km
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Insertion/withdrawal cycles (Dimensions)≥ 100
UL AWM style (Standards and Regulations)20549 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations)5 wires around filler to the core
Bending radius (Standards and Regulations)52 mm
AWG signal line (Standards and Regulations)22
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Flame resistance (Standards and Regulations)in accordance with UL 758/1581 FT2
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)LiF9YC11Y
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Conductor resistance (Standards and Regulations)max. 57 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)HB
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)70 GΩ*km (at 20 °C)
Thickness, insulation (Standards and Regulations)≥ 0.21 mm
External sheath, color (Standards and Regulations)black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations)300 V (at 20 °C)
Outer sheath thickness (Standards and Regulations)approx. 0.5 mm
Outer sheath, material (Standards and Regulations)PUR
Test voltage Core/Core (Standards and Regulations)3000 V (at 20 °C)
Conductor cross section (Standards and Regulations)5x 0.34 mm² (Signal line)
Optical shield covering (Standards and Regulations)80 %
Number of bending cycles (Standards and Regulations)10000000
Cable type (abbreviation) (Standards and Regulations)PUR
External cable diameter D (Standards and Regulations)5.25 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)42x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.27 mm ±0.02 mm (Signal line)
Dimensional drawingPlug, M12 x 1, straight, shielded (Drawings)
Smallest bending radius, fixed installation (Standards and Regulations)26 mm
Smallest bending radius, movable installation (Standards and Regulations)52 mm (up to +60°C)
Circuit diagramContact assignment of the M12 plug and the M12 socket (Drawings)
Schematic diagramPin assignment M12 male connector, 5-pos., A-coded, male side (Drawings)

Product Description

Sensor/actuator cable, 5-pole, halogen-free PUR, greyish black RAL 7021, shielded, M12 straight male connector, coding: A, a M12 straight male connector, coding: A, cable length: 0.3 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawingPlug, M12 x 1, straight, shielded

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top